[SMB-66E]
-
67
-
PARAMETER
4
Parameter
No.
Description
Setting
Range
Initial Value
Unit
42
Pulse string input
1: Pulse/Direction
2: UP/DOWN
3: A/B phase 4 times
4: A/B phase 2 times
1 to 4
1
-
45
Power-on coordinate recognition range
Specify the power-on coordinate recognition range.
The output axis is supposed to be located at a position between
"setting - 540671" and setting when the power is turned on.
0 to 540671
270335
Pulse
46
Home position output (Z-phase output) range
Enter the output range of the home position output (pulse string
mode only).
With default value 2000, the home position output remains turned on
during travel for ±2000 pulses before and after the user home
position.
Enter "0" to turn on the home position output at exactly 0 pulse in the
user coordinate.
0 to 10000
2000
Pulse
47
Positioning completion output time
Specify the interval in which the positioning completion output is
issued.
0 to 1000
100
msec
48
Controlled stop upon alarm
Select whether the controlled stop function is validated or invalidated
upon an alarm.
1: Valid. 2: Invalid
1 to 2
2
-
50
Encoder output resolution
Specify the resolution of encoder output.
Enter the number of output pulses of the pulse string output
signal.The A-/B-phase output pulse of the driver counted in four
multiples is 4 to 270336 pulses/rev.If PRM50 = 67584,
the maximum rotation speed is limited at 50rpm.After entering, turn
the power off then on again to validate the setting.
0 to 8448
16896
33792
67584
33792
pulse/
rev
51
In-position signal output mode
Select the in-position signal output mode.
0: Output even during rotation (Output if the position deviation is
within the in-position range.)
1: Do not output during rotation (Output if the position deviation is
within the in-position range and if the position command is "0.")
After setting, turn the power off then on again to validate the setting.
0 to 1
0
-
Note1 : Avoid using the parameter together with G07,G90.1, G90.2, G90.3, G91.1, G92, G92.1 and other codes that
determine the coordinate system.
Содержание AX0180
Страница 60: ...SMB 66E 52 OPERATION 2 MEMO...
Страница 88: ...SMB 66E 80 PROCESS FLOW 7 MEMO...
Страница 94: ...SMB 66E 86 PROCESS FLOW 7 MEMO...
Страница 102: ...SMB 66E 94 PROCESS FLOW 7 MEMO...