[SMB-66E]
-
62
-
PROGRAM
3
3.5 Error Code List
If a problem is found in the NC program when it is stored, a number indicating the description of the
error and the block number are displayed.
The block number indicates the block including the problem.
(The first block is supposed to be block 1.)
<Example> If an undefined code is found in block 1
Error code
Description of error
0
Undefined
1
There is no program number. The M30 code is missing.
2
Codes in the same group, simultaneous existence of which is prohibited, are in
the same block.
3
The data exceeds the setting range or the program memory overflows.
4
There is no speed designation.
5
Undefined code
6
An already registered program number is designated.
7
A duplicate O code is specified in the same program.
8
P code usage is wrong.
9
Code with missing data, or data with missing code
※
※
※
※
Enter the program only when program selection inputs (CN3-9 and 10) are turned off.
PRGM ERROR 5
BLOCK 1