PARAMETER
4
Parameter
No.
Description
Setting
Range
Initial Value
Unit
52
Function selection of I/O input signal CN3-14 (bit 9)
0: Servo-on input
1: Program stop input
After setting, turn the power off then on again to validate the setting.
0 to 1
0
-
53
Function selection of I/O input signal CN3-15(bit 10)
0: Ready return input
1: Continuous rotation stop input
After setting, turn the power off then on again to validate the setting.
0 to 1
0
-
54
Function selection of I/O input signal CN3-16(bit 11)
0: Answer input
1: Position deviation counter reset input
After setting, turn the power off then on again to validate the setting.
0 to 1
0
-
56
Function selection of I/O output signal CN3-46 (bit 13)
0: Output during indexing 1
1: Home position output
After setting, turn the power off then on again to validate the setting.
0 to 1
0
-
57
Function selection of I/O output signal CN3-47 (bit 14)
0: Output during indexing 2
1: Servo state output
After setting, turn the power off then on again to validate the setting.
0 to 1
0
-