1
)
Select “6 DvNet” from the parameter menu
and press
.
2
)
Currently set station number is displayed.
Following items can be set for DeviceNet
communication.
1: Station number
2: Baud rate
3: I/O size
Press
or
to switch between
the items that can be set.
Press
during data entry to display
the setting range for that item.
Press
to return to the original screen.
※
When a value outside of the setting range is
entered, the message on the right is displayed.
Press
MODE
after configuring the settings.
3
)
When
MODE
is pressed, the message on
the right is displayed.
e
)
Selecting “Y”
After the configured settings are stored
in the driver, the message on the right
is displayed, and the parameter menu
is displayed again.
※
※
※
※
Control power must be restarted to
validate the settings. Press
after confirming the following message.
f
)
Selecting “N”
The parameter menu is displayed again
without storing the configured settings
in the driver.
DeviceNet
ST NO. [ 0
DeviceNet
B.RATE[0]125kbps
DeviceNet
I/O SIZE[0]8byte
DeviceNet
ST NO. [ 0]
DeviceNet RNG
ST NO. 0~63
DeviceNet
REGISTERE? [Y/N]
DeviceNet
*REGISTERED*
INPUTO AGAIN
ST NO. [99]
PARA
←5RAM 6DvNet
TURN DRIVER OFF
TUEN ON AGAIN