[SMB-66E]
-
66
-
PARAMETER
4
Parameter
No.
Description
Setting
Range
Initial Value
Unit
33
Output 1 during indexing
Enables to set the output 1 (CN3-46) to be made at what
percentage of motion during positioning motion.
0% setting for no output.
0 to 99
0
%
34
Output 2 during indexing
Enables to set the output 2 (CN3-47) to be made at what
percentage of motion during positioning motion.
0% setting for no output.
0 to 99
0
%
35
Pulse rate change
Enables to set multiplier of pulses in the G72 and M6 pulse string
input modes.
1: 1 time, 2: 2 times, 3: 4 times, 4: 8 times, 5: 16times
The setting enables to determine pulses of actuator movement for
1 pulse of pulse string input.
1 to 5
1
-
36
Selection switching of I/O program numbers
Enables to select program numbers:
1: 4 bit 2 times
(BCD) (No. range 0 to 99)
2: 4 bit 2 times
(Binary) (No. range 0 to 255)
3: 5 bit 1 time
(Binary) (No. range 0 to 31)
4: 6 bit with start
(Binary)
(Program number is not set after emergency stop)(No. range 0 to 63)
5: 6-bit with start (Binary)
(Program number is set after emergency stop)(No. range 0 to 63)
1 to 5
1
-
37
Segment position range width for equal segment designation
Sets the vicinity of segment position of equal segment (G101).
1 to 270336
1500
Pulse
38
Rotation direction for equal segment designation
Specifies rotation direction for G91A0F
of equal segment
designation (G101).
1: CW
2: CCW
3: Nearer head direction
4: Alarm C outside the vicinity of equal segment position
1 to 4
3
-
(Note)
39
Torque limit
Enables to set the upper limit of torque output by percentage
against the maximum torque.
1 to 100
100
%
Note : If the settings of parameters 19, 20 and 39 are too small, alarm 1 will be caused, and the actuator may not