- 128 -
2.2.9 Panel Switch Commands
ESC c 5 n
Support model
CT-S280
CT-S300
CT-S2000
CT-S4000
CT-S251
CT-S281
CT-S310
CT-S801/851
CT-S601/651
CT-P29x series
CT-S310 II
[Function]
Enabling/disabling the panel switches
[Code]
<1B>H<63>H<35>H<n>
[Range]
0≤n≤255
[Outline]
[The specification which is common to the model]
• Enabling/disabling the FEED switch.
• “n” is valid only for the lowest bit (n0).
• Control by the lowest bit (n0) is shown as follows:
n0
Condition
0
FEED switch (LF-SW signal) valid
1
FEED switch (LF-SW signal) invalid
[Caution]
[The specification which is common to the model]
• When the FEED switch is disabled with this command, the paper cannot be fed by operating the
FEED switch.
• While switch operation is waited at the execution of macro, the FEED switch is always enabled regardless of
the setting of this command but no paper feed operation is carried out.
[Default]
n=0
CT-S801(II)
/
CT-S851(II)
• MSW3-2 OFF: n=0
• MSW3-2 ON : n=1
[Sample Program]
LPRINT CHR$(&H1B);"c5";CHR$(0); ----- When enabling the FEED switch
LPRINT CHR$(&H1B);"c5";CHR$(1); ----- When disabling the FEED switch