Page 32
PROBLEM
(6)
Blower motor wont start
(Cont.)
(7)
Blower motor wont stop
(8)
Bag wont inflate to
garment size
(9)
Inadequate air
(10) Inadequate steam
REMEDY
Check motor nameplate voltage,
machine nameplate voltage and
power line voltage, phase and
frequency. All three must be the
same.
Check timer operation. See if timer
switch operates properly. If
operation is not correct, replace the
timer.
Check to see that the blower relay
will operate properly and that the
contacts will open. If not, replace
the relay.
Increase pressure in the bag with the
pressure control lever.
Inspect damper control wire, levers
and pressure control lever. Be sure
that all parts are connected and
adjusted according to instructions.
Repair or replace any defective
parts.
Move the sizing levers until the bag
is properly sized.
Refer to bag installation instruc-
tions and check to see that bag
strings are untangled and properly
connected.
Increase pressure in the bag with the
pressure control lever.
Check to see that belt is properly
aligned and tight according to
instructions.
Set timer for longer steam time.
Inspect V belt pulley on motor shaft
to see that it is properly positioned
and set screw well tightened on
shaft flat.
Inspect V belt pulley on blower
shaft to see that it is properly
positioned and set screw well
tightened on shaft flat.
Set timer for longer steam time.
Inspect linkage and adjust according
to instructions. Repair or replace
any defective parts. Tighten all lock
nuts and set screws.
CAUSE
6E
Incorrect voltage
7A
Defective timer
7B
Defective blower relay
8A
Pressure setting too low
8B
Pressure control
defective
8C
Bag size levers not
properly set
8D
Bag improperly
installed on frame
9A
Pressure setting too low
9B
V belt loose
9C
Timer setting too short
9D
Motor pulley loose
9E
Blower pulley loose
10A
Timer setting too short
10B
Defective solenoid
linkage