2-186
Cisco ME 3800X and ME 3600X Switch Command Reference
OL-28238-01
Chapter 2 Cisco ME 3800X and ME 3600X Switch Cisco IOS Commands
network-clock hold-off
network-clock hold-off
To configure the time that the switch waits when a SyncE reference clock goes down before removing it
as the network clock, use the
network-clock hold-off
command in global configuration mode. To return
to the default value, use the no form of this command.
network-clock hold-off
value
no network-clock hold-off
value
Syntax Description
Defaults
The default hold-off time is 300 ms.
Command Modes
Global configuration
Command History
Usage Guidelines
Setting a hold-off timeout ensures that the short activation of a signal failure is not passed to the clock
selection process.
Examples
The following example shows how to set the hold-off time.
Switch#
configure terminal
Switch(config)#
network-clock hold-off 1000
Related Commands
value
Sets the time in milliseconds. The accepted values are:
•
50 to 10000 milliseconds (ms) – The timeout value.
The default is 300 ms.
•
0 = Hold-off disable
Release
Modification
15.1(2)EY
This command was introduced.
Command Description
show network-clocks
Displays network clock configuration.
show network-clock
synchronization
Displays network clock configuration.
controller BITS
commands
Configures the BITS clock controller characteristics.
Содержание ME 3600X
Страница 14: ...Contents xiv Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...
Страница 534: ... 100 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 Chapter xconnect ...
Страница 625: ...Index IN 15 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...
Страница 626: ...Index IN 16 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...
Страница 627: ...Index IN 17 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...
Страница 628: ...Index IN 18 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...