2-62
Cisco ME 3800X and ME 3600X Switch Command Reference
OL-28238-01
Chapter 2 Cisco ME 3800X and ME 3600X Switch Cisco IOS Commands
distribution
distribution
To configure statistics distributions for an IP Service Level Agreements (SLAs) Metro-Ethernet 3.0
(ITU-T Y.1731) operation, use the
distribution
command in IP SLA Y.1731 delay configuration mode.
To return to the default value, use the no form of the command.
distribution
{
delay
|
delay-variation
} {
one-way
|
two-way
}
number-of-bins
boundary
[,
...,boundary
]
no distribution {delay | delay-variation} {one-way | two-way}
Syntax Description
Defaults
The default for distribution is 10 bins with upper boundaries of 5000,
10000,15000,20000,25000,30000,35000,40000,45000,-1, for both delay and delay-variation
performance measurements.
Command Modes
IP SLA Y.1731 delay configuration (config-sla-y1731-delay)
Command History
Usage Guidelines
Use this command change the type of performance measurements to be calculated and the number and
range of distribution bins from the defaults (10 bins with upper boundaries of
5000,10000,15000,20000,25000,30000,35000,40000,45000,-1, for both delay and delay-variation
performance measurements) to the specified values.
Configure this command on the Maintenance End Point (MEP) that performs the performance
measurement calculation. For single-ended operations, calculations are performed at the sender MEP.
For dual-ended operations, calculations are performed at the receiver MEP on the responder.
delay
Specifies that the performance measurement type is delay. This is the default value,
along with delay variation.
delay-variation
Specifies that the performance measurement type is delay variation. This is the
default value, along with delay.
one-way
Specifies one-way measurement values. This is the default for a dual-ended
operation.
two-way
Specifies two-way measurement values. This is the default for a single-ended
operation.
number-of-bins
Number of bins kept during an aggregate interval. Range is from 1 to 10. Default is
10.
boundary
[,...,boundary]
List of upper boundaries for bins in microseconds. Minimum number of boundaries
required is one. Maximum allowed value for the uppermost boundary is -1
microsecond. Multiple values must be separated by a comma (,). Default is
5000,10000,15000,20000,25000,30000,35000,40000,45000, -1.
Release
Modification
15.2(4)S1
This command was introduced.
Содержание ME 3600X
Страница 14: ...Contents xiv Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...
Страница 534: ... 100 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 Chapter xconnect ...
Страница 625: ...Index IN 15 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...
Страница 626: ...Index IN 16 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...
Страница 627: ...Index IN 17 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...
Страница 628: ...Index IN 18 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...