2-7
Cisco ME 3800X and ME 3600X Switch Command Reference
OL-28238-01
Chapter 2 Cisco ME 3800X and ME 3600X Switch Cisco IOS Commands
alarm-contact
alarm-contact
To configure triggers and severity levels for external alarms, use the
alarm-contact
command in global
configuration mode. To remove the configuration, use the
no
form of this command.
alarm-contact
{
contact-number
{
description
string
|
severity
{
critical
|
major
|
minor
} |
trigger
{
closed
|
open
}} |
all
{
severity
{
critical
|
major
|
minor
} |
trigger
{
closed
|
open
}}
no alarm-contact
{
contact-number
{
description
|
severity
|
trigger
} |
all
{
severity
|
trigger
}
Defaults
No alarms are configured.
Command Modes
Global configuration
Command History
Usage Guidelines
The
no alarm-contact
contact-number
description
sets the description to an empty string.
The
no alarm-contact
{
contact-number |
all
}
severity
sets the alarm-contact severity to minor.
The
no alarm-contact
{
contact-number |
all
}
trigger
sets the external alarm-contact trigger to closed.
You can verify your settings by entering the
show env alarm-contact
or the
show running-config
privileged EXEC command.
contact-number
Configures a specific alarm contact number. The range is 1 to 4.
description
string
Adds a description for the alarm contact number. The description string can be up to
80 alphanumeric characters in length and is included in the system message
generated when the alarm is triggered.
all
Configures all alarm contacts.
severity
Sets the severity level that is set when the alarm is triggered. The severity is included
in the alarm notification. Entering
no alarm-contact severity
sets the severity to
minor.
critical
Sets severity level as critical.
major
Sets severity level as major.
minor
Sets severity level as minor.
trigger
Sets the state that triggers the alarm, whether the connected circuit is open or closed.
Entering
no alarm-contact trigger
sets the trigger to closed.
closed
Specifies that the alarm is triggered when the contact is closed.
open
Specifies that the alarm is triggered when the contact is open.
Release
Modification
12.2(52)EY
This command was introduced.
Содержание ME 3600X
Страница 14: ...Contents xiv Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...
Страница 534: ... 100 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 Chapter xconnect ...
Страница 625: ...Index IN 15 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...
Страница 626: ...Index IN 16 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...
Страница 627: ...Index IN 17 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...
Страница 628: ...Index IN 18 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...