2-82
Cisco Catalyst Blade Switch 3030 Command Reference
78-17262-01
Chapter 2 Cisco Catalyst Blade Switch 3030 Cisco IOS Commands
dot1x timeout
dot1x timeout
Use the
dot1x timeout
interface configuration command to set IEEE 802.1x timers. Use the
no
form of
this command to return to the default setting.
dot1x timeout
{
quiet-period
seconds
|
ratelimit-period
seconds
|
reauth-period
{
seconds
|
server
}
|
server-timeout
seconds
|
supp-timeout
seconds
|
tx-period
seconds
}
no dot1x timeout
{
quiet-period
|
reauth-period
|
server-timeout
|
supp-timeout
|
tx-period
}
Syntax Description
Defaults
These are the default settings:
reauth-period
is 3600 seconds.
quiet-period
is 60 seconds.
tx-period
is 5 seconds.
supp-timeout
is 30 seconds.
server-timeout
is 30 seconds.
rate-limit
is 1 second.
Command Modes
Interface configuration
quiet-period
seconds
Number of seconds that the switch remains in the quiet state following a
failed authentication exchange with the client. The range is 1 to 65535.
ratelimit-period
seconds
Number of seconds that the switch ignores Extensible Authentication
Protocol over LAN (EAPOL) packets from clients that have been
successfully authenticated during this duration. The range is 1 to 65535.
reauth-period
{
seconds
|
server
}
Set the number of seconds between re-authentication attempts.
The keywords have these meanings:
•
seconds
—Sets the number of seconds from 1 to 65535; the default is
3600 seconds.
•
server
—Sets the number of seconds as the value of the
Session-Timeout RADIUS attribute (Attribute[27]).
server-timeout
seconds
Number of seconds that the switch waits for the retransmission of packets
by the switch to the authentication server. The range is 30 to 65535.
supp-timeout
seconds
Number of seconds that the switch waits for the retransmission of packets
by the switch to the IEEE 802.1x client. The range is 30 to 65535.
tx-period
seconds
Number of seconds that the switch waits for a response to an
EAP-request/identity frame from the client before retransmitting the
request. The range is 5 to 65535.