![cias IB-SYSTEM-R Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/cias/ib-system-r/ib-system-r_installation-handbook_2606593049.webp)
CIAS Elettronica S.r.l.
Ed 2.3
Installation manual
Page
48
of
79
IB-SYSTEM-R
2.2.1 Terminal Installation
During the system installation process it is possible to use a serial terminal in order to verify the
server activity and system configuration. In order to use this function enable the serial terminal on
the server (DIP 3 of SW4 set ON), connect a normal PC to the RS485 SERVER line (see 3.5
Relay signalling page 64) through an RS232/485 converter, or by using a flat cable directly on the
back side of IB-System-R.
The following figure shows the interconnections between the computer and the server terminals.
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
8
2
0
1
7
1
9
RS232
c able
RS485
LINE
RS232/RS485
c onversion
Start the Hyper Terminal program (start -> programs -> accessories -> communication -> Hyper
Terminal), set communication parameters to 9600bps, 8 data bits, 1 stop bit, no parity, no data
flow control, as shown below.