BASIC OPERATION
3-4
CP2000-X User Manual
020-100031-01 Rev. 1 (03-2009)
DVI PORTS:
Remove the access panel and connect a wide variety of non-cinema video
and graphics sources to either of these identical single-link DVI ports.
NOTE:
These are single-link ports for single-link cable/connectors only. Using this
pair of ports as a dual-link pair requires a special adapter from Christie (available
early 2005).
RS232-B:
For connecting the
Cine-IPM 2K
only.
GPIO:
For connecting a wide range of external I/O devices to the projector, often so
that an event on one device automatically triggers an event on the other. Currently,
only inputs/outputs for 3D devices can be defined in projector software.
Lamp
Any
CP2000-X
lamp—
2, 3, 4.5,
or
6
kW—can be used with the universal 7 kW
ballast.
The lamp door must remain closed and locked for all normal operation. Trained
operators (only) can access the lamp via security key. See complete lamp
specifications in
Section 8, Specifications
.
Lens Mount & Auxiliary Lens Mount
The lens mount secures and seals a primary high-contrast zoom cinema lens within
the projector, and provides manual adjustment of focus, zoom and offset. Adjacent to
the primary mount, an optional auxiliary lens mount may be added, providing a
mechanism for positioning a 1.25x anamorphic or 1.26x Wide Converter lens in front
of the primary lens. Such a lens horizontally spreads a pre-squeezed image back into
its wider 2.39:1 “scope” image, and is most typically used in side-masking theatres.
Leveling Feet
For most cinema installations, the projector is inclined slightly forward to match
screen tilt and to minimize the amount of vertical offset required. Turn the adjustable
feet to increase or decrease projector height as needed for proper leveling and/or
slight tilt. See
2.3, Projector Position and Mounting
.
Liquid Coolant
A 50/50 mix of distilled water and ethylene glycol should fill slightly more than half
of the reservoir to ensure adequate circulation within the projection head. The
reservoir, which is located in the igniter compartment, is factory-filled and does not
require draining before projector transit. Check regularly for level and leaks, and top
up as necessary. Trained operators only.
Power Cables
Heavy-duty DC lamp cables between the ballast and the projection head are 6½ – 100
feet (2-30 meters) in length, depending on which option was ordered with the
CP2000-X
system. The ballast, projection head and heat extractor fan all include their
own line cords.