SPECIFICATIONS
CP2000-X User Manual
8-3
020-100031-01 Rev . 1 (03-2009)
7 kW 3-Phase Ballast
(38-814001-01)
Nominal Voltage per
• 208 VAC (N. America / Japan)
• 400 VAC (Europe)
Nominal Operating Range
• 200-230 ± 10% (N. America / Japan)
• 380-415 ± 10% (Europe)
Line Frequency
50-60 Hz nominal
Inrush current (max.)
note: excluding lamp
<50
A
Current consumption per phase (max.) @ 6.6
kW
• 28 A @ 208 VAC (N. America / Japan)
• 16 A @ 400 VAC (Europe)
Power consumption (max.)
• 14.4 kVA (9.1 kW), all regions
Current rating (continuous) of 3-phase AC input
at breaker
30 A, all regions
Breaker rating
50 A
BALLAST OUTPUT TO PROJECTION HEAD
Operating voltage range
18-46 VDC
Start-up voltage (open current)
125-155 VDC
Operating current range
50-180 A
Ripple
1% max @ 25°C
Control ports
See
Control Port
and
Interlock Port
on
previous page
CXL/CDXL Lamps
(kW)
Current Range
(amps)
Lamp Life (warranty hrs.)
CDXL-20 (2.0)
66-88
1200 full / 2400 pro-rated
CXL/CDXL-30 (3.0)
82-120
720 full / 1440 pro-rated
CXL/CDXL-45 (4.5)
112-150
60 full / 900 pro-rated
CXL/CDXL-60 (6.0)
126-170
50 full / 500 pro-rated
CDXL-60SD (7.0)
*
NOTE:
Current range shown includes “over-drive” of approximately 10% more than the original
lamp rating.
Type
Xenolite
®
Stand-by lamp power level for 4-6 kW
50% of lamp’s maximum current rating
Stand-by lamp power level for 2-3 kW
75% of lamp’s maximum current rating
Motorized adjustment of position
3-axis, 0.25” range for each
Recommended screen widths:
2.0 kW = 5 ft. max.
3.0 kW = 55 ft. max.
4.5 kW = 65 ft. max.
6.0 kW = 75 ft. max.
All screen sizes approximate and assuming 1.5 screen gain if <70 ft., and 1.8 screen gain if >70 ft.
70 dBA maximum (NOTE: Does not include customer-supplied external extractor
fan.)
• UL 60950-1
and
CAN/CSA C22.2. No. 60950-1-03
1
st
edition, bi-national
• IEC 60950-1:200
FCC CFR47, Part 15, Subpart B, Class A
— Unintentional Radiation
CISPR 22: 2003 +A1:2004 / EN55022: 1998 +A2:2003, Class A
—
Information Technology Equipment
CISPR 24:1997 / EN55024:1998 +A1:2001 +A2:2003 EMC Requirements
–
Information Technology Equipment
Lamps
Audible
Noise
Safety
EMC
Emissions
EMC
Immunity
Operating Environment