INSTALLATION & SETUP
2-22
CP2000-X User Manual
020-100031-01 Rev. 1 (03-2009)
Figure 2.26. Safety Cable at Projector—Flown or Front Mount
CONNECT TO POWER:
Connect the line cord of the extractor fan to the “Extractor
Fan” outlet on the rear panel of the projector. Use appropriate extension cords if
necessary. The fan will power-up with the projection head, and will run for a 10-
minute cool-down period after the projection head is powered off. This ensures
proper lamp cooling.
CALCULATE CFM in 8” DUCT:
Use an air flow meter
to measure the ft/min or ft/sec where the duct
connects to the projector (measure
at this end
only
). Then multiply the reading by the cross-
sectional area of the 8” duct (0.34) to calculate the
cubic feet/min airflow. The formula is:
Measured linear ft/min x 0.34 = CFM
NOTE:
If the duct becomes significantly blocked – or if a fan fails – the projector
should trigger an error message before becoming overheated or unsafe. Regardless,
check airflow regularly.