2-1
Install the Pedestal
2
Step 1: Mount and Level the Pedestal
•
Pull servicing wiring up through the conduit, leaving
approximately 6’ extending out of the conduit.
•
Place the pedestal over the conduit, ensuring the
long curved edge of the base plate (which is the
cut-out for a cable management kit - CMK) is
located at the back of the station.
•
Ensure the pedestal is level.
•
Fasten the pedestal to the bolts extending into the
base plate using the 5/8” nuts and washers and the
1/2” drive torque wrench with 15/16” deep socket, as
shown.
•
Adjust the lower nuts as necessary to ensure the
mounting pole is level.
•
When level, tighten the nuts on top of the base
plate to at least 90 ft-lbs (122 Nm).
•
Route the service wiring up through the pedestal.
IMPORTANT !
Ensure the pedestal is level by adjusting
the nuts underneath the base plate. Verify accuracy
after each adjustment by positioning the level at various
locations on the base plate and on the pedestal.
Before installing the pedestal, you must prepare the installation site.
For detailed instructions, see Appendix B.
5/8” nut
and