C.E.S. Model SDI-50 Manual, Level Adjustments
The format for programming all messages is:
*9
N
CC CC .... CC 08
| |
\
/ |
|
|
\ /
|
|
|
\ / |__ All messages must end with
|
|
\ /
"08".
|
|
\ /
|
|
V_____________ A two digit number is entered
|
|
to represent each character of
|
|
the message. *
|
|
|
|__________________________ One digit to identify the
|
message
being
entered
(0-4).
|
|________________________________ *9 is used to start each
message
programmed.
* - A beep tone will be sent by the SDI-50 between each two digit
character number as they are entered.
Example: To program "OFF" in the disconnect Message enter the
following: *9 (tone) 1 (tone) 63 (tone) 33 (tone) 33
(tone) 08 (tone).
Remember, when progranuning the Message's not to forget the enter the
stop bit; "08"
6.7.1
MESSAGE PROGRAMMING TABLE
CHAR.
CODE
CHAR.
CODE
CHAR.
CODE
0
00
I
43
A
37
1
10
J
51
A
38
2
20
K
52
E
39
3
30
L
53
U
47
4
40
M
61
N
44
5
50
N
62
O
45
6
60
O
63
CH
35
7
70
P
71
AR
07
8
80
Q
02
ERROR
48
9
90
R
72
,
16
A
21
S
73
-
66
B
22
T
81
.
46
C
23
U
82
/
36
D
31
V
83
?
94
E
32
W
91
SP
ERROR
96
F
33
X
92
SPACE
05
G
41
Y
93
STOP
08
H
42
Z
03
Page # 38