C.E.S. Model SDI-50 Manual, Level Adjustments
timing of your system. The Program Summary Table lists the factory
setting for these codes as well as the page specific information for
each may be found.
6.2.1 SIMPLEX SAMPLING PROGRAMMING PROCEDURE
To use the SDI-50 in the simplex sampling mode, the following changes
to the factory set-up need to be made. Any change made should be
penciled into the Program Log in the back of this manual for future
reference.
Required Programming for Simplex Operation
> Turn on Simplex Enable (*5 14) *5 14 1
> Turn off Half/Full Duplex Enable (*5 36) *5 36 O
> Set the Sample Rafe (*1 0) *1 O ?
> Set the Sample Rate Multiplier (*5 23, 24) *5 23 ?
*5 24 ?
> Set the Sample Window (*1 1) *1 1 ?
> Turn off the Repeat Enable (*5 37) *5 37 O
> JMP4 shouid be cut or removed.
6.2.2 HALF/FULL DUPLEX PROGRAMMING PROCEDURE
To use the SDI-50 in either duplex mode, the following changes to the
factory set-up need to be made. Any change made should be penciled
into the Program Log in the back of this manual for future reference.
Required Programming for Dúplex Operation
> Turn off Simplex Enable (*5 14) *5 14 O
> Turn on Half/Full Duplex Enable (*5 36) *5 36 1
> Turn on Repeat Enable (*5 37) *5 37 1
> Set the Repeater Time-Out Timer (*1 2) *1 2 ?
> Set the Repeater PTT Hang Time (*1 3) *1 3 ?
> JMP4 shouid be cut or removed if full duplex.
? = User option
> JMP4 should be intact for half duplex.
Page # 20