page 75
www.centsys.com
10.7. Appendix 7. Factory default settings
South African standard profile – ZA
Parameter description
Unit
Minimum
Default
Maximum
Menu 1 - not applicable
Menu 2
Raising collision force
Level
1
3
Max
Lowering collision force
Level
1
3
Max
Collision count
Collisions
1
4
255
Alarm output
B, T, A, X, L
1
Buzz
LCK as ESTOP
Yes or No
No
Menu 3
Autolower status
On/Off
Off
Autolower time
Mm:ss
00:00
00:30
4:00
Autolower override time
Mm:ss
00:00
00:01
00:15
Autolower on raised
On/Off
On
Autolower on partly raised
On/Off
On
Autolower on partly lowered
On/Off
Off
Menu 4
Modes of Operation
S, C, P, SP
CMX
Menu 5
Lock when raised
Yes/No
No
Lock when lowered
Yes/No
No
Holding force
%
10%
50%
100%
Raise when mains fail
On/Off
On
Pre-raising delay time
Mm:ss
00:00
00:00
01:05
Pre-lowering delay time
Mm:ss
00:00
00:00
01:05
Raising speed
Deg/sec
10 deg/sec
37 deg/sec
Max
Lowering speed
Deg/sec
10 deg/sec
37 deg/sec
Max
Ramp-up distance
Deg
3 deg
7 deg
15 deg
Ramp-down distance
Deg
3 deg
7 deg
15 deg
TRG stop distance
Deg
5 deg
10 deg
30 deg
Loop stop distance
Deg
5 deg
10 deg
30 deg
Crawl distance
Deg
1 deg
1 deg
5 deg
Torque limit
A
5A
15A
15A
APPENDICES