10.1 Courtesy Light Status
The courtesy light feature can be turned ON or OFF, independent of any other settings
associated with the feature. The courtesy light feature is turned off by default.
If the feature is turned OFF, the physical output associated with the feature (configured in
Menu 10.2) will be driven to, and remain in, an inactive state.
10.2 Courtesy Light Function Output
The outputs are listed in the table below, along with the relevant electrical characteristics
of the respective outputs:
10.3 Courtesy Light Profile
One of four lighting profiles can be selected based on the table below:
The profile controls the light to act as a courtesy light. Any barrier activation will switch
on the light. The light stays on while the barrier moves, or during any form of pre-delay.
Once the barrier is stationary, the light will remain on for the time set by the ‘Courtesy
Light Time’ setting. After which, the light will switch off.
Pre-Flash A Profile (PFA)
– The light will only switch on while the barrier is moving.
The light will switch off or remain off in all stationary states, even those states that pre-
empt movement (pre-open delay, pre-close delay)
Pre-Flash B Profile (PFB)
– The light will flash while the barrier is moving, and during
any states that pre-empt movement (pre-open delay, pre-close delay)
Pre-Flash C Profile (PFC)
– The light behaves identically to Pre-Flash B profile except it
doesn’t flash, it simply switches on.
10.4 Courtesy Light Timer
When the pole comes to rest after any form of barrier movement (manual movement of
the barrier is discounted), the controller enters a courtesy light phase. During this period,
if the courtesy light profile is enabled, the courtesy light will switch on (or remain on). At
the end of the courtesy light period, the light will switch off.
The ‘Courtesy Light Time’ setting specifies the time period of the courtesy light phase. It
can be set from 4 seconds to 9h59m59s in 1 second increments.
TABLE 8
Output setting
on controller
Output
Description
Output
Type
Electrical Switch Characteristics
RLY
Relay
Dry Contact
24V DC/250V AC, 2A contact
XIO
Aux IO
Open Drain
Open Drain – 3A sink current, with a
3V floating terminal Voltage.
AUX
Aux Out
Open Drain
Open Drain – 3A sink current
LED
Status LED
Open Collector
Open Collector 5V – 50mA Source
Light Profile
Profile Description
CUR
Courtesy Light Profile
PFA
Pre-Flash A
PFB
Pre-Flash B
PFC
Pre-Flash C
TABLE 9
ADVANCED CONTROLLER SETUP