Cedima • Technical Documentation • Joint Cutter CF•1020 D • Issue date: 21/09/2021
81
V-belts
Maintenance, Repairs and Shut-Down
8.3.2 Replacing V-belts
Safety instructions: Store removed parts together!
Many screws and small parts will be removed in the following steps. So that all parts can be
found again during assembly, collect and store the removed parts in a suitable location, e.g.
in a cardboard box.
• The machine is switched off and secured against accidental switch-on, see the chapter
"Operation" > "Daily shut-down" (page 72).
• If necessary, the blade guard must be removed, see the chapter "Set-Up" > "Removing
and fitting blade guard" (page 56).
• If necessary, the diamond saw blade must be removed, see the chapter "Set-Up" > "Re-
moving and fitting diamond saw blade" (page 53).
• Three V-belts
• Allen key (10 mm)
• Two spanners (17 mm)
• Suitable protective gloves
Carry out the following steps:
1.
Using the
"
two
SpannErS
"
(17 mm), unscrew the two
"
faStEning
ScrEwS
"
of the
"
protEctivE
covEr
of
thE
cutting
Shaft
"
.
2.
Remove the
"
protEctivE
covEr
of
thE
cutting
Shaft
"
.
Condition:
Required:
Remove protective
covers