background image

                         Refer headi

ng “Computer Connectivity – for Call Logging & Call Voice Recording

” for further details.

 

                       - For Door Lock operation, insert the 3 Pin stereo Plug here. The Shield point of the Plug is the common  
                         point. Whene

ver, Door Lock operation command is given by any Extension, the “Shield Point” shorts with  

                         the following points of the Jack

:

 

                                           Tip point of the Plug 

– in case of the 2

nd

 Door Lock 

                                           Next to the Tip point of the Plug 

– in case of the 1st Door Lock 

                                           The above shorting acts as a simple switch. 
                                    Note

:

 2

nd

 Door Lock operation is Optional. 

    

Music

           For connecting External music for Music on Hold.  

                         Insert the 3 Pin stereo Plug of the external Music source, here. 
    

COM

            - The Battery Lead provided with the system is to be connected here.  

                           Connect 2 SMF rechargeable Batteries (12V 7AH) in series and connect to the Battery Lead. The RED  
                           wire is to be connected to the +ve Terminal of the Battery and Black to the 

–ve Terminal. The 2  

                           batteries are to be connected in series with the help of a red colored shorting lead provided with the  
                           system. The battery connections are on Pin number 5 & 6. Pin 5 = Gnd and Pin 6 = + 24V DC. 

                   - It can also be connected to a Serial Port of a PC, for operating PC Software for transferring Junction call  
                    details to PC. This is Optional and required PC Software Management. With this option , a special 9 pin to  
                    9 pin lead is provided. That lead would have battery connections as well within it. 

                           With that lead following connections are made: 
                                  PBX side connector               PC side serial port connector 
                                           Pin 2                                                 Pin 3  
                                           Pin 3                                                 Pin 2  
                                           Pin 5                                                 Pin 5  
    

LINE 1 

        Terminate the 1st Junction Line here through a RJ Connector. 

    

LINE 2 

        Terminate the 2nd Junction Line here through a RJ Connector. 

    LINE 3 

        Terminate the 3rd Junction Line here through a RJ Connector. 

    LINE 4 

        Terminate the 4th Junction Line here through a RJ Connector. 

    LINE 5 

        Terminate the 5th Junction Line here through a RJ Connector. 

    LINE 6 

        Terminate the 6th Junction Line here through a RJ Connector. 

    LINE 7 

        Terminate the 7th Junction Line here through a RJ Connector. 

    LINE 8 

        Terminate the 8th Junction Line here through a RJ Connector. 

    

EXT 601 

   Terminate the 1st Extension wires over here through a RJ Connector. 

    EXT 602 

   Terminate the 2nd Extension wires over here through a RJ Connector. 

    EXT 603 

   Terminate the 3rd Extension wires over here through a RJ Connector. 

    EXT 604 

   Terminate the 4th Extension wires over here through a RJ Connector. 

    EXT 605 

   Terminate the 5th Extension wires over here through a RJ Connector. 

    EXT 606 

   Terminate the 6th Extension wires over here through a RJ Connector. 

    EXT 607 

   Terminate the 7th Extension wires over here through a RJ Connector. 

    EXT 608 

   Terminate the 8th Extension wires over here through a RJ Connector. 

     

…………………………. 

     

……………………… 

    EXT 632 

   Terminate the 32nd Extension wires over here through a RJ Connector. 

 

    AC 220V 

   Connect the 3 pin main lead here. Make sure that the EARTH wire 

                       connected to it is coming directly from the point where EARTH is created.  
    

On/Off  

    Switch 
    on Side  
    panel of  
    the PBX  

    It is for switching the PBX ON / OFF. In OFF position the Batteries keep charging. 

Note

:

 The PBX is supplied RJ Connectors with short leads for terminating the cables to RJ Sockets. It is recommended to  

          crimp RJ connectors directly to the cables in order to maintain the aesthetics. 

Night Facility 

-

 

In default first 4 Junction lines are defined for Night Facility on Extension number 605 to 608. For this setting, all the 8 pins of the DIP  
Switch on CPU card should be in ON position. 

-

 

In case 8 Junction Lines are used, then Pin no 1,3,5 & 7 of DIP Switch should be in OFF position on the CPU Card. 

 

Precautions

-

 

The Mains AC socket from where the PBX is given 220 V AC, should be separately made by taking direct connections from 
the MCB Box and no other Electrical appliance should be connected on this point. 

 

 
 
 
 
 
 
 
 
 
 
 

 

.

         

 
 
 
 
 

Содержание COX-308 HSK

Страница 1: ...nection Auto Answer on KTS Auto Attendant Operations Auto Attendant Message Modes Auto Attendant Voice message of 8 Secs Auto Attendant Voice message of 20 Secs Auto Attendant Playing a Company messag...

Страница 2: ...ssword Redial Recall from Received or Dialed Out Numbers Data Bank Remote Programming Resetting the PBX programming Ring Time Settings Ring Tone Change Walking Class of Service Terms of Warranty Notes...

Страница 3: ...cted to the EPABX should not have more than 5 volts on it 3 PIN AC Plug GOOD EARTHING BAD EARTHING Voltmeter reading between N E must be more than 100mV and less than 5V If voltmeter reading between N...

Страница 4: ...ere through a RJ Connector LINE 5 Terminate the 5th Junction Line here through a RJ Connector LINE 6 Terminate the 6th Junction Line here through a RJ Connector LINE 7 Terminate the 7th Junction Line...

Страница 5: ...g junction internal calls 10 HOLD STORE For holding a junction internal call and also used while programming 11 SP PHONE EXIT To activate hands free mode of KTS 12 Navigation Key Volume Adjustment key...

Страница 6: ...s Dial 0000 05 NN HH MM Where NN Last 2 digits of the extension number HH 00 23 Hours MM 00 59 Minutes Dial 0000 05 To clear Alarm of all extensions Dial 0000 05 NN To clear Alarm of NN extension To s...

Страница 7: ...different situations explained below If the Caller dials an extension other than the Operator and the extension is busy the call will ring on the Operator At this moment the extension gets an Alert t...

Страница 8: ...king in 20 Secs message mode Auto Attendant Playing a Company message while the call is ringing on an extension Paradoxically this option works in Direct Ring Mode and not Auto Attendant Mode This fea...

Страница 9: ...as Junction calls Secretary can call the BOSS directly Call Billing Call Recording Monitoring Hotel Management The PBX stores approximately 3 000 last Junction calls dialed out record in its memory T...

Страница 10: ...e original Extension Dial 26 NN To clear the feature of NN Extension from any of the programming Extension Dial 26 To clear the Call Forward Always feature of all the extensions To be dialed from any...

Страница 11: ...k the call One or more Junction calls can be parked from any extension by dialing FLASH Dial from the same extension or from any other extension to retrieve the first parked call Dial 9 from the same...

Страница 12: ...s in FSK mode in default For other modes Dial 0000 1811 for DTMF mode Dial 0000 1810 for FSK mode Note The above programming is true for SLT as well as KTS However KTS has an option to do the above th...

Страница 13: ...ll end Between 2 Junction From SLT Extension During conversation with a Junction line FLASH Dial Pick up another Junction by dialing 9 dial required Tel number FLASH Dial 6 Conference will start Exten...

Страница 14: ...Day mode Note 0440 0441 and 0442 will work if Junction Ring Assignment is set in Auto Attendant Mode Dial 22 From any of the KTS to shift to Auto Change Mode Dial 23 From any of the KTS to shift to M...

Страница 15: ...e ring assignment Day Mode Ring To assign extensions to ring in Day mode when Door Phone calls Dial 0000 82 NN Where NN 01 32 Representing the Extension numbers from 601 to 632 Repeat the program for...

Страница 16: ...Extension numbers in default are from 601 to 632 and can be changed to 2 digit 3 digit or 4 digits numbering as explained under the heading Flexible Numbering Process Lift Handset Dial Extension Numb...

Страница 17: ...rmal mode Dial 0000 884 To convert all Extensions in normal mode In case of Hot Line following time delay can be set Dial 0000 189 TT Where TT 01 99 seconds It is the time within which the extension c...

Страница 18: ...N Last 2 digits of Extension number L 0 The Extension can dial only the numbers starting with digits defined in Allowed Table 1 The Extension can dial all numbers 2 The Extension can dial all numbers...

Страница 19: ...ter the lapse of this time The FLASH function to Hold an Incoming Junction call starts working after the lapse of this time To change this delay time Dial 0000 03 TT Where TT 01 to 99 secs Default val...

Страница 20: ...n Ring Assignment can be set in combination with Simultaneous Ring i e some extension would ring in Simultaneous mode and some in Round Robin mode for the same Junction Line ring To enter many extensi...

Страница 21: ...de DAY CO CA IN Junction Ring in Day Mode SEPC CO PREFIX LCR starting codes NOR CO OUT NUM Access code of normal Junctions SPEC CO OUT NUM Access code for Special Junctions SPE CALL IN OUT Special Jun...

Страница 22: ...ill get a dummy dial tone Then if he dials a number starting with 0 then the number will be dialed through Junction line number 4 5 or 6 Memory Dialing User can store up to 48 Telephone Numbers in the...

Страница 23: ...e the 1st Operator Extension Dial 0000 150NN Where NN Last 2 digits of Extension which is to be made the 1st Operator To change the 2nd Operator Extension Dial 0000 151NN Where NN Last 2 digits of Ext...

Страница 24: ...Dial 0000 0000 To erase only Flexible numbering of the PBX Dial 0000 9000 Note The above programming is true for SLT as well as KTS However KTS has an option to do the above through another process g...

Страница 25: ...are applicable a The product has been subjected to abnormal use abnormal condition improper storage exposure to moisture or dampness exposure to excessive temperature or fire etc unauthorised modifica...

Отзывы:

Похожие инструкции для COX-308 HSK