Refer headi
ng “Computer Connectivity – for Call Logging & Call Voice Recording
” for further details.
- For Door Lock operation, insert the 3 Pin stereo Plug here. The Shield point of the Plug is the common
point. Whene
ver, Door Lock operation command is given by any Extension, the “Shield Point” shorts with
the following points of the Jack
:
Tip point of the Plug
– in case of the 2
nd
Door Lock
Next to the Tip point of the Plug
– in case of the 1st Door Lock
The above shorting acts as a simple switch.
Note
:
2
nd
Door Lock operation is Optional.
Music
For connecting External music for Music on Hold.
Insert the 3 Pin stereo Plug of the external Music source, here.
COM
- The Battery Lead provided with the system is to be connected here.
Connect 2 SMF rechargeable Batteries (12V 7AH) in series and connect to the Battery Lead. The RED
wire is to be connected to the +ve Terminal of the Battery and Black to the
–ve Terminal. The 2
batteries are to be connected in series with the help of a red colored shorting lead provided with the
system. The battery connections are on Pin number 5 & 6. Pin 5 = Gnd and Pin 6 = + 24V DC.
- It can also be connected to a Serial Port of a PC, for operating PC Software for transferring Junction call
details to PC. This is Optional and required PC Software Management. With this option , a special 9 pin to
9 pin lead is provided. That lead would have battery connections as well within it.
With that lead following connections are made:
PBX side connector PC side serial port connector
Pin 2 Pin 3
Pin 3 Pin 2
Pin 5 Pin 5
LINE 1
Terminate the 1st Junction Line here through a RJ Connector.
LINE 2
Terminate the 2nd Junction Line here through a RJ Connector.
LINE 3
Terminate the 3rd Junction Line here through a RJ Connector.
LINE 4
Terminate the 4th Junction Line here through a RJ Connector.
LINE 5
Terminate the 5th Junction Line here through a RJ Connector.
LINE 6
Terminate the 6th Junction Line here through a RJ Connector.
LINE 7
Terminate the 7th Junction Line here through a RJ Connector.
LINE 8
Terminate the 8th Junction Line here through a RJ Connector.
EXT 601
Terminate the 1st Extension wires over here through a RJ Connector.
EXT 602
Terminate the 2nd Extension wires over here through a RJ Connector.
EXT 603
Terminate the 3rd Extension wires over here through a RJ Connector.
EXT 604
Terminate the 4th Extension wires over here through a RJ Connector.
EXT 605
Terminate the 5th Extension wires over here through a RJ Connector.
EXT 606
Terminate the 6th Extension wires over here through a RJ Connector.
EXT 607
Terminate the 7th Extension wires over here through a RJ Connector.
EXT 608
Terminate the 8th Extension wires over here through a RJ Connector.
………………………….
………………………
EXT 632
Terminate the 32nd Extension wires over here through a RJ Connector.
AC 220V
Connect the 3 pin main lead here. Make sure that the EARTH wire
connected to it is coming directly from the point where EARTH is created.
On/Off
Switch
on Side
panel of
the PBX
It is for switching the PBX ON / OFF. In OFF position the Batteries keep charging.
Note
:
The PBX is supplied RJ Connectors with short leads for terminating the cables to RJ Sockets. It is recommended to
crimp RJ connectors directly to the cables in order to maintain the aesthetics.
Night Facility
-
In default first 4 Junction lines are defined for Night Facility on Extension number 605 to 608. For this setting, all the 8 pins of the DIP
Switch on CPU card should be in ON position.
-
In case 8 Junction Lines are used, then Pin no 1,3,5 & 7 of DIP Switch should be in OFF position on the CPU Card.
Precautions
:
-
The Mains AC socket from where the PBX is given 220 V AC, should be separately made by taking direct connections from
the MCB Box and no other Electrical appliance should be connected on this point.
.