background image

                                L = Class of Service  

                    = 0  - 

The Extension can dial only the numbers starting with digits defined in “Allowed Table” 

                       1  - The Extension can dial all numbers. 
                       2  - The Extension can dial all numbers except for ISD numbers. 
                       3  - The Extension can dial all numbers except for STD numbers. 

                                      4   - The Extension can dial all numbers except for the numbers starting with digits defined in  
                                             

“Denied Table-A” 

    5- The Extension can dial all numbers except for the numbers starting with digits defined in  
        

“Denied Table-B” 

                                      6  - The Extension cannot dial out but can make internal calls.

 

Operating Procedure from SLT / KTS 
     Lift Handset 
     Dial #5 PPPP 

– Get Internal Dial Tone – Dial 9 - Get Junction Dial Tone – now dial the required Telephone Number 

     Example:   If we create with Pass Word = 1234 and L = 1 
                      Now to make a call from any extension,  
                      Lift Handset 
                      Dial #5 1234 
                      Hear the Junction Dial Tone 
                      Dial 9 + any Telephone number (Local, STD or ISD)  

Note:

 This Virtual User Pass Word would work from extensions which are programmed as below

:

 

              

Under the heading “Junction Dialing Controls”, L should be 0. 

                 i.e., In the program, Dial #

0000 +  44 NN L #    Here, L should be = 0. 

Deleting a User 

     Dial #*0000 # 5 NN #

 

Deleting all the User 

     Dial #*0000 # 500 # 

.

                                                         Terms of Warranty                                                                          

.

 

Copper Connections Pvt. Ltd. warrants that this product is manufactured under stringent quality standards, making it free from defects in material and workmanship, 
as per the following terms and conditions: 
1. 

The limited warranty for the system is valid for a period of twelve months from the date of purchase or fifteen months from the date of manufacture which ever 
is earlier. 

2. 

The limited warranty extends only to the original consumer/ purchaser of the product and is not assignable or transferable to any subsequent purchaser/end 
user. 

3. 

During the limited warranty period, Copper Connections Pvt. Ltd. or its authorised service network will repair or replace, at Copper Connections Pvt. Ltd. option, 
any defective product or parts thereof with a new or factory rebuild replacement items and return the product to the consumer in working conditions. No charge 
will be made to the consumer for either parts or labour in repairing or replacing the product. All replaced parts shall become the property of Copper Connections 
Pvt. Ltd..                                                                                                                                                                                    

4. 

Repaired product will be warranted for a balance of original warranty period. 

5. 

Upon request from Copper Connections Pvt. Ltd. or its authorised service center, the consumer must provide purchase receipt or other information to prove the 
date and place of purchase. 

6. 

The consumer shall have no benefit or coverage if any of the following conditions are applicable: 
a) 

The  product  has  been  subjected  to  abnormal  use,  abnormal  condition,  improper  storage,  exposure  to  moisture  or  dampness,  exposure  to  excessive 
temperature or fire etc., unauthorised modifications,   unauthorised connections, unauthorised repairs including but not limited to use of unauthorised spare 
parts in repairs, misuse, neglect, abuse, accident, alteration, improper installation. 

b) 

Copper Connections Pvt. Ltd. was not notified by consumer of the alleged defect or malfunction of the product during the limited warranty period. 

c)   The product was used with or connected to equipment not fit for use with Copper Connections Pvt. Ltd. system or used in other than its intended use. 

d) 

THE SYSTEM IS NOT CONNECTED TO A PROPER EARTH OR INCASE HIGH VOLTAGES APPEAR ON EARTH.  

e) 

THE  DAMAGE  IS  CAUSED  BY  LIGHTENING  ON  EXTENSIONS/  JUNCTION  LINES/  OR  SPIKES/  SURGES/  HIGH  VOLTAGES  FROM  AC  MAIN 
SUPPLY. 

7. 

The consumer may contact the authorised dealer to call the service personnel for carrying out repairs or maintenance and the same would be attended within 
a reasonable response time assigned to the dealer. 

8. 

The consumer will be billed for parts or labour charges not covered by this limited warranty. 

9. 

If the product is brought to Copper Connections Pvt. Ltd. for repairs, after the warranty period Copper Connections Pvt. Ltd. normal service policy shall apply 
and customer shall be charged accordingly. 

10.  In no event shall Copper Connections Pvt. Ltd. or their authorised dealer be liable for special or consequential damages or any delay in the performance of this 

warranty due to causes beyond their control. Copper Connections Pvt. Ltd. shall not be liable for incidental or consequential damage or a loss of anticipated 
benefits or profits, loss or impairment of privacy of conversation, work stoppage or loss or impairment of data arising out of the use or inability to use the product. 

11.  Copper Connections Pvt. Ltd. neither assumes nor authorises any authorised service center or any person or entity to assume for it any other obligation or 

liability beyond what is expressly provided by this limited warranty. All warranty information, product features and specifications are subject to change without 
prior notice. 

12.  Any dispute arising out of this warranty shall be subjected to jurisdiction of the arbitrator within the city of Delhi. 
13.   The decision of Copper Connections Pvt. Ltd., on defects, damages etc shall be final and binding on the parties and no dispute regarding this, could  
        be agitated before any civil court.

                                                                                                                                                 

Part No- 832 MNL- 23

 

       

                                                                    _______________________________________ 

 

ISO 9001:2008 Certified company

 

 

Copper Connections Pvt. Ltd

 

195-196, DSIDC Complex, Okhla Industrial Area, Ph-1, New Delhi-110020. Ph: +91-11-40625555 

www.copperconnections.com

 

Содержание COX-308 HSK

Страница 1: ...nection Auto Answer on KTS Auto Attendant Operations Auto Attendant Message Modes Auto Attendant Voice message of 8 Secs Auto Attendant Voice message of 20 Secs Auto Attendant Playing a Company messag...

Страница 2: ...ssword Redial Recall from Received or Dialed Out Numbers Data Bank Remote Programming Resetting the PBX programming Ring Time Settings Ring Tone Change Walking Class of Service Terms of Warranty Notes...

Страница 3: ...cted to the EPABX should not have more than 5 volts on it 3 PIN AC Plug GOOD EARTHING BAD EARTHING Voltmeter reading between N E must be more than 100mV and less than 5V If voltmeter reading between N...

Страница 4: ...ere through a RJ Connector LINE 5 Terminate the 5th Junction Line here through a RJ Connector LINE 6 Terminate the 6th Junction Line here through a RJ Connector LINE 7 Terminate the 7th Junction Line...

Страница 5: ...g junction internal calls 10 HOLD STORE For holding a junction internal call and also used while programming 11 SP PHONE EXIT To activate hands free mode of KTS 12 Navigation Key Volume Adjustment key...

Страница 6: ...s Dial 0000 05 NN HH MM Where NN Last 2 digits of the extension number HH 00 23 Hours MM 00 59 Minutes Dial 0000 05 To clear Alarm of all extensions Dial 0000 05 NN To clear Alarm of NN extension To s...

Страница 7: ...different situations explained below If the Caller dials an extension other than the Operator and the extension is busy the call will ring on the Operator At this moment the extension gets an Alert t...

Страница 8: ...king in 20 Secs message mode Auto Attendant Playing a Company message while the call is ringing on an extension Paradoxically this option works in Direct Ring Mode and not Auto Attendant Mode This fea...

Страница 9: ...as Junction calls Secretary can call the BOSS directly Call Billing Call Recording Monitoring Hotel Management The PBX stores approximately 3 000 last Junction calls dialed out record in its memory T...

Страница 10: ...e original Extension Dial 26 NN To clear the feature of NN Extension from any of the programming Extension Dial 26 To clear the Call Forward Always feature of all the extensions To be dialed from any...

Страница 11: ...k the call One or more Junction calls can be parked from any extension by dialing FLASH Dial from the same extension or from any other extension to retrieve the first parked call Dial 9 from the same...

Страница 12: ...s in FSK mode in default For other modes Dial 0000 1811 for DTMF mode Dial 0000 1810 for FSK mode Note The above programming is true for SLT as well as KTS However KTS has an option to do the above th...

Страница 13: ...ll end Between 2 Junction From SLT Extension During conversation with a Junction line FLASH Dial Pick up another Junction by dialing 9 dial required Tel number FLASH Dial 6 Conference will start Exten...

Страница 14: ...Day mode Note 0440 0441 and 0442 will work if Junction Ring Assignment is set in Auto Attendant Mode Dial 22 From any of the KTS to shift to Auto Change Mode Dial 23 From any of the KTS to shift to M...

Страница 15: ...e ring assignment Day Mode Ring To assign extensions to ring in Day mode when Door Phone calls Dial 0000 82 NN Where NN 01 32 Representing the Extension numbers from 601 to 632 Repeat the program for...

Страница 16: ...Extension numbers in default are from 601 to 632 and can be changed to 2 digit 3 digit or 4 digits numbering as explained under the heading Flexible Numbering Process Lift Handset Dial Extension Numb...

Страница 17: ...rmal mode Dial 0000 884 To convert all Extensions in normal mode In case of Hot Line following time delay can be set Dial 0000 189 TT Where TT 01 99 seconds It is the time within which the extension c...

Страница 18: ...N Last 2 digits of Extension number L 0 The Extension can dial only the numbers starting with digits defined in Allowed Table 1 The Extension can dial all numbers 2 The Extension can dial all numbers...

Страница 19: ...ter the lapse of this time The FLASH function to Hold an Incoming Junction call starts working after the lapse of this time To change this delay time Dial 0000 03 TT Where TT 01 to 99 secs Default val...

Страница 20: ...n Ring Assignment can be set in combination with Simultaneous Ring i e some extension would ring in Simultaneous mode and some in Round Robin mode for the same Junction Line ring To enter many extensi...

Страница 21: ...de DAY CO CA IN Junction Ring in Day Mode SEPC CO PREFIX LCR starting codes NOR CO OUT NUM Access code of normal Junctions SPEC CO OUT NUM Access code for Special Junctions SPE CALL IN OUT Special Jun...

Страница 22: ...ill get a dummy dial tone Then if he dials a number starting with 0 then the number will be dialed through Junction line number 4 5 or 6 Memory Dialing User can store up to 48 Telephone Numbers in the...

Страница 23: ...e the 1st Operator Extension Dial 0000 150NN Where NN Last 2 digits of Extension which is to be made the 1st Operator To change the 2nd Operator Extension Dial 0000 151NN Where NN Last 2 digits of Ext...

Страница 24: ...Dial 0000 0000 To erase only Flexible numbering of the PBX Dial 0000 9000 Note The above programming is true for SLT as well as KTS However KTS has an option to do the above through another process g...

Страница 25: ...are applicable a The product has been subjected to abnormal use abnormal condition improper storage exposure to moisture or dampness exposure to excessive temperature or fire etc unauthorised modifica...

Отзывы:

Похожие инструкции для COX-308 HSK