Introduction
.
Maximum capacity of the PBX:
Model
Junction Lines
Extensions
Door Phones
connectivity
Door Locks
connectivity
832 HSK
8
Numbered as 1
to 8 having
access code as
#11, #12,#13 to
#18
32
-
Out of 32 Extensions 4 Ports can be
used as KTS as well as SLT
extensions and 28 are to be used as
SLT only.
-
Numbered as 601 to 632
-
602 is the first Operator and 601 the
second.
-
Programming can be done from 601,
602, 603 & 604
4
1 Door Phone
consumes 1
Extension port.
2
2
nd
Lock
connection is
Optional
308 HSK
3
Numbered as 1
to 3 having
access code as
#11, #12 and
#13
8
-
Out of 8 Extensions 4 Ports can be
used as KTS as well as SLT
extensions and 4 are to be used as
SLT only.
-
Numbered as 601 to 608
-
602 is the first Operator and 601 the
second.
-
Programming can be done from 601,
602, 603 & 604
4
1 Door Phone
consumes 1
Extension port.
2
2
nd
Lock
Operation is
Optional
.
Installation
.
Cabling
-
All cables of the EPABX should be at least 6” away from the electrical cables.
-
The KTS Extensions need 4 Core cables. SLT Extensions need 2 Core Cables.
-
They should be at least 12” away from the area of high frequencies like tube light
chokes, Electric Motors, etc. If it is not possible to avoid, then use shielded cables
and earth the shield.
Earthing
Earth connected to the EPABX should not have more than 5 volts on it.
3 PIN AC Plug
GOOD EARTHING
BAD EARTHING
Voltmeter reading between N & E
must be more than 100mV and
less than 5V
If voltmeter reading between
N & E is more than 5V, do
not run the Copper
Connections System on it.
Location
-
The PBX should be installed in a well ventilated area and at a place where there is no chance of liquid spilling over it or
moisture getting into it (Like in the Bathrooms etc).
-
Direct sun light should not fall on the PBX.
-
The PBX should be installed on the wall at a minimum of 2 ft height from the floor.
Note: The Compan
y’s warrantee voids if the above points are not followed.
Front Panel Indications
The PBX has a Black Plastic on the front panel.
When PBX is put ON, a RED Led (in the middle of the black plastic) blinks fast indicating that the PBX is configuring itself. After
few seconds, the LED blinks slower indicating that the PBX is now running OK.
There are 8 LED’s corresponding to the 8 Junction lines. They get ON whenever the corresponding Junction Line is assessed by
any Extension.
Connections
The PBX has the following connectors on its side panel:
Connectors Description
Broadcast
- In default this connector is configured for Door Lock Operation.
/
Door
- It can Optionally be used for Paging through an external PA Amplifier or to record conversation of
Extension / Junction. This Option has to be mentioned while placing order with the company.
V
E
.
N
.