                 Here, X= 0 for Day Mode and 1 for Night mode. 
                          J = 1 to 8 (Junction Line no) 
                          NN  = Last 2 digits of the Extension No. 
         This programming can be repeated for one Junction Line and up to 16 Extensions. 
         One Junction line can be programmed to land on up to 16 Extensions. 
       Dial #

0000 + 3X J #  (To disable Ring Assignment of one Junction) 

       Dial #

0000 + 3X J NN 1 #  (To disable Ring Assignment of one Junction & Extension) 

Default

:

 All the Junction Lines land on Extension number 601 and 602 in Simultaneous Mode. 

Round Robin Ring  

In this mode, the incoming call lands on one extension. If that extension is busy or doesn’t respond within few rings then the call shifts to another 
extension. 

Programming

:

 

#

0000 + 3X J #            This program 

disables the default ring assignment

.

 

#

0000 + 3 X J NN 0 #  Here, X= 0 for Day Mode and 1 for Night mode. 

                                            J = 1 to 4 (Junction Line no) 
                                        NN  = Last 2 digits of the 1

st

 Round Robin Extension No.

(Not the Flexible Number) 

                                                 Also note that the first Extension in Round Robin can be 601 to 616 only. 

                                                 Cannot program Extension 617 to 632 in case of 432S. 
# 27 NN  XXX       Where, XXX= 2

nd

 Extension number of Round Robin Extensions. If flexible numbering is done then  

                                                    enter the Flexible number. 

If the Flexible number is say 26 then XXX will be = 26 & not  

                                                    026.

 

                                            NN= The last 2 digits of the 

1st Extension number (Not the flexible number

)

 

# 27 NN  XXX       Where, XXX= 3rd Extension number of Round Robin Extensions. If flexible numbering is done then  
                                                    enter the Flexible number. 

If the Flexible number is say 26 then XXX will be = 26 & not  

                                                    026.

 

                                            NN= The last 2 digits of the 

2nd Extension number (Not the flexible number

)

 

# 27 NN  XXX       Where, XXX= 4th Extension number of Round Robin Extensions. If flexible numbering is done then  
                                                    enter the Flexible number. 

If the Flexible number is say 26 then XXX will be = 26 & not  

                                                    026.

 

                                            NN= The last 2 digits of the 

3rd Extension number (Not the flexible number

)

 

Note

:

 Round Robin Ring Assignment can be set in combination with Simultaneous Ring i.e., some extension would ring in  

         Simultaneous mode and some in Round Robin mode for the same Junction Line ring. 
       

:

 To enter many extensions without entering password again and again, following is an example for the procedure:  

         To assign Extension numbers 601, 602 & 605 to ring for incoming calls on Junction  number 2, in 

Day Mode:

 

              Dial #

0000 + 30 + 2 # + 30 2 01 0 # + 30 2 02 0 # + 30 2 05 0 # 

Example: 

To assign Round Robin to 601, 602, 604 and then 603 

                   Dial #

0000 + 3 0 1 # 

                         #

0000 + 3 0 1 01 0 # 

                         #27 01 602 
                         #27 02 604 
                         #27 04 603 
                   Dial #

0000 + 3 0 2 # 

                         #

0000 + 3 0 2 01 0 # 

                   Dial #

0000 + 3 0 3 # 

                         #

0000 + 3 0 3 01 0 # 

Options when all assigned extensions are busy 

When the extensions assigned for the Junction incoming call are busy, following options can be set: 
         Dial #

0000 + 1880# (The assigned extension when busy, will hear a waiting call beep after every 5 seconds) 

                                      This is the default setting.

 

         Dial #

0000 + 1881# 

(The call will land on the first available extension starting from 601, 602, …to … 632)

 

 

.

                                                                          

Junction - Enable / Disable                                                                  

.

 

The PBX has auto detect feature whereby it detects whether a Junction line is connected on its Junction port or not. 
As we connect a Junction line to the PBX, the corresponding Junction port gets Enabled. As we remove a Junction line, the 
corresponding Junction port gets Disabled. 
To avoid continuous glow of DSS keys of unused Junction ports, on KTS, assign the DSS keys to Extensions. 
 

.

                                                                                

Junction to Junction Forwarding                                                    

.

 

Making 2 Junction lines talk to each other while Ext remains out of the conversation. 

During conversation with a Junction line - Hook-Flash - # # 

(To park the Call)

 

– 0 – Tel No (who is to be connected to the previous 

Junction call) 

– Hook Flash - # 6 - Now all 3 party can talk to each other but Ext can keep Handset down.  

The 2 Junction lines will hear a tone after 80 seconds and if any of them presses * then they can talk for another 90 seconds. Like 
this they can keep extending the talk time. If * is not pressed then the calls will disconnect. If they wish to disconnect in between 
then any of them need to dial #. 

Содержание COX-308 HSK

Страница 1: ...nection Auto Answer on KTS Auto Attendant Operations Auto Attendant Message Modes Auto Attendant Voice message of 8 Secs Auto Attendant Voice message of 20 Secs Auto Attendant Playing a Company messag...

Страница 2: ...ssword Redial Recall from Received or Dialed Out Numbers Data Bank Remote Programming Resetting the PBX programming Ring Time Settings Ring Tone Change Walking Class of Service Terms of Warranty Notes...

Страница 3: ...cted to the EPABX should not have more than 5 volts on it 3 PIN AC Plug GOOD EARTHING BAD EARTHING Voltmeter reading between N E must be more than 100mV and less than 5V If voltmeter reading between N...

Страница 4: ...ere through a RJ Connector LINE 5 Terminate the 5th Junction Line here through a RJ Connector LINE 6 Terminate the 6th Junction Line here through a RJ Connector LINE 7 Terminate the 7th Junction Line...

Страница 5: ...g junction internal calls 10 HOLD STORE For holding a junction internal call and also used while programming 11 SP PHONE EXIT To activate hands free mode of KTS 12 Navigation Key Volume Adjustment key...

Страница 6: ...s Dial 0000 05 NN HH MM Where NN Last 2 digits of the extension number HH 00 23 Hours MM 00 59 Minutes Dial 0000 05 To clear Alarm of all extensions Dial 0000 05 NN To clear Alarm of NN extension To s...

Страница 7: ...different situations explained below If the Caller dials an extension other than the Operator and the extension is busy the call will ring on the Operator At this moment the extension gets an Alert t...

Страница 8: ...king in 20 Secs message mode Auto Attendant Playing a Company message while the call is ringing on an extension Paradoxically this option works in Direct Ring Mode and not Auto Attendant Mode This fea...

Страница 9: ...as Junction calls Secretary can call the BOSS directly Call Billing Call Recording Monitoring Hotel Management The PBX stores approximately 3 000 last Junction calls dialed out record in its memory T...

Страница 10: ...e original Extension Dial 26 NN To clear the feature of NN Extension from any of the programming Extension Dial 26 To clear the Call Forward Always feature of all the extensions To be dialed from any...

Страница 11: ...k the call One or more Junction calls can be parked from any extension by dialing FLASH Dial from the same extension or from any other extension to retrieve the first parked call Dial 9 from the same...

Страница 12: ...s in FSK mode in default For other modes Dial 0000 1811 for DTMF mode Dial 0000 1810 for FSK mode Note The above programming is true for SLT as well as KTS However KTS has an option to do the above th...

Страница 13: ...ll end Between 2 Junction From SLT Extension During conversation with a Junction line FLASH Dial Pick up another Junction by dialing 9 dial required Tel number FLASH Dial 6 Conference will start Exten...

Страница 14: ...Day mode Note 0440 0441 and 0442 will work if Junction Ring Assignment is set in Auto Attendant Mode Dial 22 From any of the KTS to shift to Auto Change Mode Dial 23 From any of the KTS to shift to M...

Страница 15: ...e ring assignment Day Mode Ring To assign extensions to ring in Day mode when Door Phone calls Dial 0000 82 NN Where NN 01 32 Representing the Extension numbers from 601 to 632 Repeat the program for...

Страница 16: ...Extension numbers in default are from 601 to 632 and can be changed to 2 digit 3 digit or 4 digits numbering as explained under the heading Flexible Numbering Process Lift Handset Dial Extension Numb...

Страница 17: ...rmal mode Dial 0000 884 To convert all Extensions in normal mode In case of Hot Line following time delay can be set Dial 0000 189 TT Where TT 01 99 seconds It is the time within which the extension c...

Страница 18: ...N Last 2 digits of Extension number L 0 The Extension can dial only the numbers starting with digits defined in Allowed Table 1 The Extension can dial all numbers 2 The Extension can dial all numbers...

Страница 19: ...ter the lapse of this time The FLASH function to Hold an Incoming Junction call starts working after the lapse of this time To change this delay time Dial 0000 03 TT Where TT 01 to 99 secs Default val...

Страница 20: ...n Ring Assignment can be set in combination with Simultaneous Ring i e some extension would ring in Simultaneous mode and some in Round Robin mode for the same Junction Line ring To enter many extensi...

Страница 21: ...de DAY CO CA IN Junction Ring in Day Mode SEPC CO PREFIX LCR starting codes NOR CO OUT NUM Access code of normal Junctions SPEC CO OUT NUM Access code for Special Junctions SPE CALL IN OUT Special Jun...

Страница 22: ...ill get a dummy dial tone Then if he dials a number starting with 0 then the number will be dialed through Junction line number 4 5 or 6 Memory Dialing User can store up to 48 Telephone Numbers in the...

Страница 23: ...e the 1st Operator Extension Dial 0000 150NN Where NN Last 2 digits of Extension which is to be made the 1st Operator To change the 2nd Operator Extension Dial 0000 151NN Where NN Last 2 digits of Ext...

Страница 24: ...Dial 0000 0000 To erase only Flexible numbering of the PBX Dial 0000 9000 Note The above programming is true for SLT as well as KTS However KTS has an option to do the above through another process g...