7 - MAINTENANCE
Battery fluid level
WARNING
Hazardous chemicals!
Battery electrolyte contains sulfuric acid. Contact with skin and eyes could result in severe irritation
and burns. Always wear splash-proof goggles and protective clothing (gloves and aprons). Wash
hands after handling.
Failure to comply could result in death or serious injury.
W0006A
Check the battery fluid level every 500 hours of operation or every 120 days, whichever comes first.
Check the battery fluid level if the machine has not been operated in a long time.
Check the fluid on a monthly basis if the machine is operated in very warm climates.
1.
Shut down the engine.
2.
Clean the area around the battery to prevent external
material or contaminants from entering the battery
vent wells.
NOTICE:
Use caution when working with metallic tools or
conductors. Contact can create sparks and short circuits.
3.
Use a Phillips head screwdriver and remove the caps
(2)
for the vent wells
(1)
.
RCPH10TLB291AAF
1
4.
Check the fluid level in each vent cell. Specification
(2)
is
3 - 10 mm
(
0.12 - 0.39 in
) from the base of the
vent well
(1)
to the start of the electrolyte level.
5.
Add distilled water to each cell as needed.
6.
Reinstall the vent cap and tighten the screw. Do not
overtighten! Screw torque must not exceed
1 N·m
(
12 lb in
).
7.
In temperatures of
0 °C
(
32 °F
) and below, connect
a battery charger to the batteries (or run the engine)
for approximately two hours to ensure the electrolyte
mixes with the added water.
RCPH10TLB396AAF
2
7-74
Содержание 570NXT
Страница 8: ......
Страница 23: ...1 GENERAL INFORMATION Symbol Definition Less than Greater than mg kg Milligrams per kilogram 1 15 ...
Страница 24: ...1 GENERAL INFORMATION 1 16 ...
Страница 88: ...3 CONTROLS INSTRUMENTS 3 28 ...
Страница 142: ...6 WORKING OPERATIONS 6 34 ...
Страница 167: ...7 MAINTENANCE Adjust Interval Page no Maintenance action No of pts As required 7 102 Disable parking brake X 7 25 ...
Страница 193: ...7 MAINTENANCE Cylinder closed end Two total one on each side RCPH10TLB258AAF 3 7 51 ...
Страница 197: ...7 MAINTENANCE 15 Check the fluid level and add if necessary Refer to page 7 41 for the procedure 7 55 ...
Страница 252: ...7 MAINTENANCE 7 110 ...
Страница 257: ...8 SPECIFICATIONS Machine overall dimensions 8 5 ...
Страница 259: ...8 SPECIFICATIONS RAIL12UTL0182GA 1 8 7 ...
Страница 260: ...8 SPECIFICATIONS 8 8 ...
Страница 262: ...8 SPECIFICATIONS RAIL12UTL0182GA 2 8 10 ...
Страница 272: ...9 ACCESSORIES 9 4 ...
Страница 279: ......