7 - MAINTENANCE
Every 50 hours
Fuel system water separator
Drain the water separator and check the fuel for water or sediment every 50 hours.
NOTE:
A clear bowl allows a visible check of the fuel for
water. If water or sediment are present, drain water out of
the filter and the fuel tank.
RAIL11TLB0009AA
1
1.
Remove the wire connector attached to the bottom
of the drain valve for the water separator.
NOTE:
View is from underneath the machine.
RAIL11TLB0007AA
2
•
Press on the wire clasp that holds the connec-
tor to the drain to remove.
RCPH10TLB031AAF
3
2.
Hold a small container under the water separator and
loosen the drain valve.
3.
Collect a small amount of fluid and inspect for water
or sediment.
4.
Drain until water or sediment is no longer present.
5.
Close the drain valve.
7-45
Содержание 570NXT
Страница 8: ......
Страница 23: ...1 GENERAL INFORMATION Symbol Definition Less than Greater than mg kg Milligrams per kilogram 1 15 ...
Страница 24: ...1 GENERAL INFORMATION 1 16 ...
Страница 88: ...3 CONTROLS INSTRUMENTS 3 28 ...
Страница 142: ...6 WORKING OPERATIONS 6 34 ...
Страница 167: ...7 MAINTENANCE Adjust Interval Page no Maintenance action No of pts As required 7 102 Disable parking brake X 7 25 ...
Страница 193: ...7 MAINTENANCE Cylinder closed end Two total one on each side RCPH10TLB258AAF 3 7 51 ...
Страница 197: ...7 MAINTENANCE 15 Check the fluid level and add if necessary Refer to page 7 41 for the procedure 7 55 ...
Страница 252: ...7 MAINTENANCE 7 110 ...
Страница 257: ...8 SPECIFICATIONS Machine overall dimensions 8 5 ...
Страница 259: ...8 SPECIFICATIONS RAIL12UTL0182GA 1 8 7 ...
Страница 260: ...8 SPECIFICATIONS 8 8 ...
Страница 262: ...8 SPECIFICATIONS RAIL12UTL0182GA 2 8 10 ...
Страница 272: ...9 ACCESSORIES 9 4 ...
Страница 279: ......