![Carrier Weathermaster 48P2030-100 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/carrier/weathermaster-48p2030-100/weathermaster-48p2030-100_controls-start-up-operation-service-and-troubleshooting_2560338021.webp)
21
Table 15 — Fan Performance — 50P2,P3060 Units with Discharge Plenum and 50P4,P5060 Units
LEGEND
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.
2. See Component Pressure Drop data table before using Fan Perfor-
mance tables.
3. Conversion — Bhp to kW:
See Physical Data table for motor efficiency.
AIRFLOW
(cfm)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
12,000
241
1.82
280
2.41
314
3.04
346
3.72
376
4.47
405
5.26
433
6.11
460
7.01
15,000
281
3.14
316
3.87
346
4.61
374
5.38
400
6.19
426
7.05
450
7.95
474
8.90
18,000
323
5.03
355
5.92
382
6.80
408
7.68
431
8.58
454
9.53
476
10.50
498
11.52
21,000
366
7.61
395
8.66
421
9.69
444
10.71
466
11.73
487
12.78
507
13.85
527
14.94
24,000
410
10.97
437
12.20
460
13.39
482
14.55
503
15.71
523
16.88
541
18.07
560
19.27
27,000
455
15.23
479
16.65
501
18.00
522
19.33
542
20.64
560
21.95
578
23.26
595
24.58
30,000
500
20.52
522
22.11
543
23.64
563
25.14
581
26.61
599
28.06
616
29.52
632
30.97
AIRFLOW
(cfm)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
12,000
486
7.94
511
8.91
535
9.91
559
10.94
581
11.99
603
13.07
624
14.16
645
15.28
15,000
498
9.90
520
10.93
543
12.01
564
13.11
586
14.26
606
15.43
627
16.63
646
17.86
18,000
518
12.57
539
13.66
559
14.78
579
15.95
598
17.15
617
18.39
636
19.65
654
20.95
21,000
546
16.07
564
17.23
583
18.42
600
19.64
618
20.90
635
22.19
653
23.51
669
24.86
24,000
577
20.49
594
21.74
611
23.00
628
24.31
644
25.63
660
26.99
676
28.38
691
29.77
27,000
611
25.91
628
27.26
643
28.63
659
30.03
674
31.44
689
32.87
703
34.33
718
35.82
30,000
648
32.43
663
33.90
678
35.38
—
—
—
—
—
—
—
—
—
—
AIRFLOW
(cfm)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
12,000
664
16.40
683
17.55
702
18.70
720
19.87
15,000
666
19.12
685
20.39
703
21.69
721
23.01
18,000
672
22.28
690
23.64
708
25.02
725
26.44
21,000
686
26.25
703
27.67
719
29.11
735
30.59
24,000
707
31.23
722
32.71
737
34.20
—
—
27,000
—
—
—
—
—
—
—
—
30,000
—
—
—
—
—
—
—
—
50P3,P5 units only.
Bhp —
Brake Horsepower
Kilowatts =
Bhp x 0.746
Motor efficiency
Содержание Weathermaster 48P2030-100
Страница 130: ...130 Fig 19 Typical Power Schematic Sizes 040 075 Shown ...
Страница 131: ...131 Fig 20 Main Base Board Input Output Connections ...
Страница 132: ...132 Fig 21 RXB EXB CEM SCB Input Output Connections ...
Страница 133: ...133 Fig 22 Typical Gas Heat Unit Control Wiring 48P030 100 Units Shown ...
Страница 134: ...134 Fig 23 Typical Electric Heat Wiring 50P030 100 Units Shown ...
Страница 135: ...135 Fig 24 Typical Power Wiring 115 V ...
Страница 136: ...136 Fig 25 Typical Gas Heat Section Size 030 050 Units Shown ...
Страница 138: ...138 Fig 27 Component Arrangement Size 030 035 Units ...
Страница 139: ...139 Fig 28 Component Arrangement Size 040 075 Units ...
Страница 140: ...140 Fig 29 Component Arrangement Size 090 100 Units ...