Rev.01 - 06.2021 | LDP1/LDP2 Single and Dual Loop Detector | © 2021 |
CARLO GAVAZZI Industri
11
ENEN
6. Dip Switch
DIP Switch settings for Single Loop (LDD1)
12
3
4
56
78
91
01
11
2
ON
ON
RESET
1
2
3
4 5 6 7
8
9
10
SENSITIVITY
RELAY 1
LOOP
RELAY 2
12
3
4
56
78
91
01
11
2
ON
78
CT
S
DIP SWITCH 1 - Frequency mode selection
The Loop Detector operates on one out of four channels. If the Loop Detector is located near sources
of electrical or magnetic disturbances, e.g. from other Loop Detectors, some channels can be more
advantageous to use than others. Two Loop Detectors placed in close proximity of each other should
use different channels to avoid crosstalk between the loops.
• When DIP SWITCH 1 is set to
ON
, the user manually selects which channel is used by setting DIP
switch 2 and 3.
Frequency settings
1
Selection
mode
Automatic channel selection
Manual channel selection
2
Channel
selection
DIP switch 2 and 3 are not used in
automatic channel selection
1
2
3
4
3
General settings
4
Turn-on delay
Delay OFF
Delay 2.0 sec
5
ASB
ASB OFF
ASB ON
6
Failure mode
Fail safe
Fail secure
Relay 1 settings
7
Output mode
Pulse mode
Presence mode
8
Time
0.1 sec pulse
0.5 sec pulse
Infinite
60 min
10 min
1 min
9
Entry / Exit
Vehicle entry
Vehicle exit
Relay 2 settings
10 Output mode
Pulse mode
Presence mode
11
Time
0.1 sec pulse
0.5 sec pulse
Infinite
60 min
10 min
1 min
12
Entry / Exit
Vehicle entry
Vehicle exit