Options
SPX II Series
60
Operating Manual
03.17
Press key
to arrive the next parameter.
Moving up and down of pad.
If the pad does not reach the corresponding final position within the
set time, then an error message appears ('final position above' at
moving up and/or 'final position below' at moving down).
Value range: 0
… 5000 ms
Step size: 10 ms
Default: 0 ms
Press key
to arrive the next parameter.
Stroke adjust
The arrester can be adjusted and the stroke speed can be set. The
pad makes a stroke movement and return again to the basic position
after reaching the lower end position.
Press key
to start the stroke movement.
Press key
to arrive the next parameter.
This menu serves for the applicator setup as well as for error tracing.
Input signals of the applicator can be monitored and output signals
can be set or reset separately. With keys
and
the
corresponding output for setting and/or resetting the output signals
can be selected. With keys
and
the corresponding output can
be set or reset.
Input signals
I
1
=
Pre-dispense key (1 = key pressed, 0 = key not pressed)
I
2
=
Final position up (1 = pad in final position up,
0 = pad not in final position up)
I
3
=
Final position down (1 = pad in final position down,
0 = pad not in final position down)
I
4
=
Compressed air (1 = compressed air available,
0 = no compressed air available)
I
5
=
Vacuum (1 = vacuum at pad available, 0 = no vacuum at pad
available)
Output signals
O
1
=
Move pad downwards (1 = On, 0 = Off)
O
2
=
Move pad upwards (1 = On, 0 = Off)
O
3
=
not assigned
O
4
=
not assigned
O
5
=
Blowing air (1 = On, 0 = Off)
O
6
=
Supporting air (1 = On, 0 = Off)
O
7
=
Vacuum pad (1 = On, 0 = Off)
Stroke timeout
Test functions
Input/Output