Additional Information
SPX II Series
96
Operating Manual
03.17
11.2 Hotstart
NOTICE!
The data is saved onto CF card. Therefore the CF card is a
condition for the
Hotstart
menu item.
The function
Hotstart
contains e.g. that in case of a power failure the
currently loaded label can be further processed without any loss of
data. Moreover a print order can be interrupted and to be continued
after switching on the print module anew.
NOTICE!
At an active
Hotstart
all necessary data is stored on the CF card
therefore do not remove the card during operation. When
removing during operation, this causes the loss of all data on
the CF card.
In case the
Hotstart
function is set to on, at the start of a print order
the data of the current label is saved to the corresponding directory of
the CF card.
However the following conditions have to be fulfilled:
CF card inserted in drive A.
CF card not write-protected.
Enough free storage space onto CF card.
An error message appears in case these conditions are not fulfilled.
At switching off the print module the state of the current print order is
saved to the corresponding directory of the CF card.
However the following conditions have to be fulfilled:
CF card inserted in drive A.
CF card not write-protected.
Enough free storage space onto CF card.
When restarting the print module (if the function
Hotstart
is activated)
the saved label data and the status of print order were loaded from the
corresponding file on the CF card. Because of this reason, when
switching on the print module a CF card has to be inserted in the
appropriate drive. If the data cannot be loaded an error message
appears.
Saving the
current label
Saving the print
order state
Loading a label and