SPX II Series
Function Menu
03.17
Operating Manual
49
6.9 Interface
Switch on the print module and the display shows the main menu.
Press key
to access the function menu.
Press key
as long as you arrive the
Interface
menu.
Press key
to select the menu.
COM1:
0 - serial interface Off.
1 - serial interface On.
2 - serial Interface On, no error message occurs in case of a
transmission error.
Baud:
Indication of bits which are transferred per second (speed of data
transfer).
Value range: 1200, 2400, 4800, 9600, 19200, 38400, 57600 and
115200.
P = Parity:
N - No parity; E - Even; O - Odd
Please observe that the settings correspond to those of the direct print
module.
D = Data bits:
Setting of data bits.
Value range: 7 or 8 Bits.
S = Stop bits:
Indication of stop bits between bytes.
Value range: 1 or 2 stop bits.
Press key
to arrive the next menu item.
SOH:
Start of data transfer block
Hex format 01
ETB:
End of data transfer block
Hex formal 17
Two different start / en signs can be set. The settings are normally
SOH = 01 HEX and ETB = 17 HEX. Several host computers cannot
process these signs and therefore SOH = 5E HEX and ETB = 5F
cannot be set.
Press key
to arrive the next menu item.
Standard:
After starting a print order the print module buffer receives
data as long as it is filled.
Advanced:
During a current print order data is received and
processed.
Off:
After starting a print order no more data is received.
Press key
to arrive the next menu item.
Check whether the data are transferred via the interface.
Press the
and
keys to select standard (on). Press the
key and the data sent via any port (COM1, LPT, USB, TCP/IP) is
printed.
COM1 / Baud /
P / D / S
Start sign / End sign
Data memory
Porttest