Apply-Print:
Before starting the cyclic operation 'apply-print', the printing and
picking up of the first label has to be released separately by a special
signal.
The pad with the printed label is in starting position and the vacuum at
the pad is switched on.
At start of the cyclic operation when sending the start signal, the first
label is already on the pad. The following process is similar to the
mode 'print-apply' but at the end of the cycle the next label is printed
and picked up by the pad.
Now the labelling cycle is finished.
Press key
to arrive the next parameter.
The vacuum is connected not immediately with print start, but only if
the label were put forward a certain time. This delay causes that the
label runs more easily under the pad as it is not sucked and in this
way braked.
Value range: 0
… 2500 ms
Step size: 10 ms
Default: 0 ms
Press key
to arrive the next parameter.
The supporting air from the blow tube is not immediately switched on
at print start but only if the label has covered a distance.
This delay helps to prevent a turning or swinging at the front of the
label and consequently avoids faults when the label is being picked up
from print module.
Value range: 0
… 2500 ms
Step size: 0 ms
Default: 0 ms
Press key
to arrive the next parameter.
Delayed to the process of the label being picked up, the supporting air
is switched off.
In many cases, after being picked up by the pad the label edge may
still stick on the liner. This may affect the accuracy of the label
positioning or even cause faults in the labelling. Therefore, switching
off the air blow delayed can be useful to separate the label from liner
and neatly place the label on the surface of pad.
Value range: 0
… 2500 ms
Step size: 10 ms
Default: 500 ms
Press key
to arrive the next parameter.
With activated compressed air control, with help from a compressed
air sensor it is checked at each labelling cycle if the compressed air
fits with the valve block. If no compressed air is presented, the
labelling cycle is stopped and the error message 'compressed air' is
displayed.
If the parameter 'pressure control' is set to Off, the error treatment as
described above will not be effected. This can be especially helpful at
initiation of the labelling system.
For standard operation, set the parameter to On..
Vacuum delay
Support delay On
Support delay Off
Pressure control