Function menu
Dynacode series
64 Operating
manual
10.15
7.16 Service functions
In order that the distributor res. the manufacturer can provide
fast support in case of malfunction, the direct print module is
equipped with the Service functions menu.
Necessary information such as set parameters is indicated
directly at the direct print module.
More information such as firmware or font version is shown in
main menu (see chapter 7.17 on page 67).
Press key
to access the function menu.
Press key
as long as you arrive at the 'Service functions' menu.
Press key
to select the menu.
Photocell parameters:
H
= cover switch.
0 = open cover; 1 = closed cover.
P
= compressed air control
Value range: 0 or 1.
R1
= transfer ribbon rewinding roll
Indication of transfer ribbon rewinding roll status.
4 states are indicated (no marking in photocell, marking from right,
marking from left, marking completely in photocell).
R2
= transfer ribbon unwinding roll
Indication of transfer ribbon unwinding roll status.
4 states are indicated (no marking in photocell, marking from right,
marking from left, marking completely in photocell).
C
= Carriage
Indication of print carriage position.
ENC
= Encoder
Indication of current state of encoder
Press key
to arrive at the next menu item.
Paper counter:
D:
Indication of printhead attainment in meters.
G:
Indication of direct print module attainment in meters.
Press key
to arrive at the next menu item.
Heater resistance:
To achieve a high print quality, the indicated Ohm value must be set
after an exchange of printhead.
Press key
to arrive at the next menu item.
Printhead temperature:
Indication of printhead temperature. The printhead temperature
corresponds normally to the room temperature. In case the maximum
printhead temperature is exceeded, the current print order is
interrupted and an error message appears at the direct print module
display.
Press key
to arrive at the next menu item.
Ribbon / Ink side:
Ribbon:
Selection of the used transfer ribbon length (300 m, 450 m,
600 m, 900 m or 1000 m). With smaller ribbons, a higher number of
cycles can be reached.
Ink side:
Selection of the coating side of transfer ribbon, either outside or
inside.
Default: Coating outside
Содержание DYNACODE
Страница 1: ...DYNACODE Operating Manual ...
Страница 10: ......
Страница 22: ...Technical data Dynacode series 22 Operating manual 10 15 Example 1 Example 2 Example 3 ...
Страница 36: ......
Страница 40: ......
Страница 44: ......
Страница 70: ......
Страница 80: ......
Страница 96: ......
Страница 102: ......
Страница 115: ...Dynacode series Index 10 15 Operating manual 113 T Technical data 17 U Unpacking 29 W Warnings 12 ...