Function menu
Dynacode series
50 Operating
manual
10.15
7.4 Machine parameters (continuous mode)
Press key
to access the function menu.
Press key
as long as you arrive at the 'Machine parameters'
menu.
Press key
to select the menu.
Mode:
It is not possible to start printing by the interface. The machine is
always in control mode and the print is released by the control input
'print start'. The operating mode is normally transferred with each
layout otherwise mode 'I/O dynamic continuous' is used as standard
operating mode.
With keys and you have the possibility to select res. change the
operating mode. At the moment the following modes are available:
IO ST = IO static:
The input signal is evaluated, i.e. it is printed as long as the signal
exists. The number of layouts, which was entered at print start, is
printed (level evaluation of print start signal).
IO ST F = IO static continuous:
Corresponds to IO static. Continuous means that not only a defined
number of pieces is processed but the same layout is printed as long
as new data is transferred by interface.
IO DY = IO dynamic:
The external signal is evaluated dynamically, i.e. in case the direct
print module is in 'waiting' mode a single layout is printed at each
signal changing (flank evaluation of print start signal).
IO DY F = IO dynamic continuous:
Corresponds to IO dynamic. Continuous means that not only a
defined number of pieces is processed but the same layout is printed
as long as new data is transferred by interface.
Test mode:
This operating mode corresponds to mode 2. After the return of the
print unit to the zero point of the machine, however, internally a further
cycle is started (endurance test).
Direct start:
A print order is transferred. After termination of generating process the
print order is executed without an external signal.
Содержание DYNACODE
Страница 1: ...DYNACODE Operating Manual ...
Страница 10: ......
Страница 22: ...Technical data Dynacode series 22 Operating manual 10 15 Example 1 Example 2 Example 3 ...
Страница 36: ......
Страница 40: ......
Страница 44: ......
Страница 70: ......
Страница 80: ......
Страница 96: ......
Страница 102: ......
Страница 115: ...Dynacode series Index 10 15 Operating manual 113 T Technical data 17 U Unpacking 29 W Warnings 12 ...