Ribbon save
Dynacode series
104 Operating
manual
10.15
Press key
to arrive at the next menu item.
PHupT = printhead up time in ms:
Is used from ribbon save algorithm to calculate if a field ribbon save
can be made or not.
PhVReactT = valve reaction time in ms:
It is calculated when the printhead upwards movement is started.
Press key
to arrive at the next menu item.
RibMotStpDlayT = ribbon motor stop delay time
Decelaration time in ms in which the transfer ribbon motor is still
moved with constant speed before stopping.
This can be used to correct black bars at the end of print or to provide
a longer cooling for the printhead.
Press key
to arrive at the next menu item.
FieldRS = field ribbon saving:
Off:
Field ribbon save mode Off.
PHOnly:
Only the printhead is moved. The transfer ribbon is not
stopped.
Normal:
Field ribbon save is executed only if the transfer ribbon motor
is completely stopped.
Strong:
Field ribbon save is executed, even if the transfer ribbon
motor is not stopped.
Rwind v = rewind speed in mm/s:
Indication of rewind in mm/s.
Press key
to arrive at the next menu item.
Speed 1. Field:
If 0 (default value) is set, the parameter has no influence to the ribbon
save. Otherwise the ribbon save algorithm does not use the measured
speed for the calculation of layout ribbon save but the speed that is
indicated here.
Press key
to arrive at the next menu item.
Tension:
Indication of length, which is transported forward after measuring the
transfer ribbon.
Содержание DYNACODE
Страница 1: ...DYNACODE Operating Manual ...
Страница 10: ......
Страница 22: ...Technical data Dynacode series 22 Operating manual 10 15 Example 1 Example 2 Example 3 ...
Страница 36: ......
Страница 40: ......
Страница 44: ......
Страница 70: ......
Страница 80: ......
Страница 96: ......
Страница 102: ......
Страница 115: ...Dynacode series Index 10 15 Operating manual 113 T Technical data 17 U Unpacking 29 W Warnings 12 ...