Dynacode series
Installation and Initiation
10.15 Operating
manual
33
4.3 Adjustment of pressure power
Pressure power in dependence
of air pressure c53 / i53
(one pressure cylinder)
0
1
2
3
4
5
2
3
4
5
Air pressure in bar
P
res
su
re
i
n
k
g
Lift 1 mm
Lift 2 mm
Lift 3 mm
Pressure power in dependence
of air pressure c107 / i107
(two pressure cylinder)
0
1
2
3
4
5
6
7
8
2
3
4
5
Air pressure in bar
P
res
su
re i
n
k
g
Lift 1 mm
Lift 2 mm
Lift 3 mm
Pressure power in dependence
of air pressure c128 / i128
(two pressure cylinders)
0
1
2
3
4
5
6
7
8
2
3
4
5
Air pressure in bar
P
res
su
re i
n
k
g
Lift 1 mm
Lift 2 mm
Lift 3 mm
The pressure power of the printhead can be set with the pressure
regulator. The values are indicated in the following table:
In case the pressure power is set too low, it is possible that the
printhead has no contact to the counter-pressure plate. Because
of the missing heat during the print this could damage the
printhead. In this case an error message appears. This error
message is only to protect the printhead for overheating and is not
to use as print quality control.
The lift indicates the distance between printhead and brake stator in
'print less' status.
Dynacode 53
Dynacode 107 Dynacode 128
Recommended pressure
power:
40 N
40 N
40 N
Max. pressure power:
45 N
45 N
45 N
As the mechanical wear and tear of the printhead increases with the
pressure power, the pressure power should be as low as possible.
Содержание DYNACODE
Страница 1: ...DYNACODE Operating Manual ...
Страница 10: ......
Страница 22: ...Technical data Dynacode series 22 Operating manual 10 15 Example 1 Example 2 Example 3 ...
Страница 36: ......
Страница 40: ......
Страница 44: ......
Страница 70: ......
Страница 80: ......
Страница 96: ......
Страница 102: ......
Страница 115: ...Dynacode series Index 10 15 Operating manual 113 T Technical data 17 U Unpacking 29 W Warnings 12 ...