Dynacode series
Ribbon save
10.15 Operating
manual 103
Press key
to arrive at the next menu item.
Performance information:
sa/mm:
The smallest possible distance of two prints with full ribbon
save (the print offset must be set to the minimum value). As basis for
the calculation the set ribbon save parameters are used, as well as
mode and especially the indicated max. print speed.
cmin:
Max. number of cycles per minute.
so/mm:
Indicates the loss of ribbon save, i.e. how many mm transfer
ribbon is effectively lost.
Press key
to arrive at the next menu item.
ExpertParameters:
This menu item is password protected. Enter password, press key
to confirm the input and the following parameters are indicated:
PhDownT = printhead down time in ms:
This is used from ribbon save algorithm for the calculation of start time
of printhead upwards movement.
REStartT = ribbon motor early start time in ms:
This value is added to the increase time of transfer ribbon movement.
Time indication for the time between 'motor reached material speed'
and 'printhead burns'.
If the same value is entered as for PhDownT, the printhead upwards
movement is not started before the transfer ribbon motor reached the
material speed.
Press key
to arrive at the next menu item.
MinSpeed = minimal print speed:
If the min. print speed is increased, the max. number of cycles is also
increased.
Calcoff = Turn On/Off print offset border calculation:
If this parameter is set to Off, then a smaller offset as the required
print offset can be entered.
Содержание DYNACODE
Страница 1: ...DYNACODE Operating Manual ...
Страница 10: ......
Страница 22: ...Technical data Dynacode series 22 Operating manual 10 15 Example 1 Example 2 Example 3 ...
Страница 36: ......
Страница 40: ......
Страница 44: ......
Страница 70: ......
Страница 80: ......
Страница 96: ......
Страница 102: ......
Страница 115: ...Dynacode series Index 10 15 Operating manual 113 T Technical data 17 U Unpacking 29 W Warnings 12 ...