7
7
7-18
7-18
Error Code > Error Code > Error Code Details > E202 to E280
Error Code > Error Code > Error Code Details > E202 to E280
E
Code
Detail
Code
Location
Item
Description
E240 -0001
-05
Title
3 minutes passed with pickup request waiting status
Remedy
1. Check the connection of the Connector.
2. Check the connection of the Sub PCB in the Main
Controller PCB 1 Box.
3. Check the connections of the DC Controller PCB and the
Main Controller PCB 1. Replace the PCB(s) if necessary.
Description It was detected that 3 minutes passed with pickup request
waiting status.
E240 -0002
-05
Title
3 minutes passed with image output request waiting status
Remedy
1. Check the connection of the Connector.
2. Check the connection of the Sub PCB in the Main
Controller PCB 1 Box.
3. Check the connections of the DC Controller PCB and the
Main Controller PCB 1. Replace the PCB(s) if necessary.
Description It was detected that 3 minutes passed with image output
request waiting status.
E240 -0003
-05
Title
Software sequence error after the jam
Remedy
1. Check the connection of the Connector.
2. Check the connection of the Sub PCB in the Main
Controller PCB 1 Box.
3. Check the connections of the DC Controller PCB and the
Main Controller PCB 1. Replace the PCB(s) if necessary.
Description A software sequence error (engine bug) was detected after
the jam.
E246 -0001
-00
Title
System error
Remedy
Contact to the sales companies.
Description ---
E246 -0002
-00
Title
System error
Remedy
Contact to the sales companies.
Description ---
E246 -0003
-00
Title
System error
Remedy
Contact to the sales companies.
Description ---
E246 -0005
-00
Title
System error
Remedy
Contact to the sales companies.
Description ---
E247 -0001
-00
Title
System error
Remedy
Contact to the sales companies.
Description ---
E
Code
Detail
Code
Location
Item
Description
E247 -0002
-00
Title
System error
Remedy
Contact to the sales companies.
Description ---
E247 -0003
-00
Title
System error
Remedy
Contact to the sales companies.
Description ---
E247 -0004
-00
Title
System error
Remedy
Contact to the sales companies.
Description ---
E248 -0000
-00
Title
SRAM error
Remedy
Main Controller PCB 2.
Description SRAM check error when the power is turned ON.
E248 -0001
-04
Title
EEPROM error
Remedy
Failure of the Reader Controller PCB (PCB1).
Description An error when EEPROM power for the Reader Controller
PCB (PCB1) is turned ON.
E248 -0002
-04
Title
EEPROM error
Remedy
Failure of the Reader Controller PCB (PCB1).
Description EEPROM writing error for the Reader Controller PCB (PCB1).
E248 -0003
-04
Title
EEPROM error
Remedy
Failure of the Reader Controller PCB (PCB1).
Description Reading error after writing to EEPROM for the Reader
Controller PCB (PCB1).
E263 -0000
-05
Title
Error in Current Sensor reference voltage generation
Remedy
1. Check the connection between the AC Driver PCB and the
Main Driver PCB (connector disconnection, open circuit,
short circuit of harness).
AC Driver side: J615, Main Driver side: J103
2. Replace the AC Driver PCB.
3. Replace the Main Driver PCB (PCB2).
Description When CP54 on the Main Driver PCB was measured with a
tester, the reference voltage (normally 2.5 V) was not within
the range of reference value (2.2 to 2.7 V).
Содержание imageRUNNER ADVANCE 6075 Series
Страница 4: ...Blank Page ...
Страница 318: ...3 3 Periodic Service Periodic Service Periodical Service Operation Item ...
Страница 565: ...5 5 Adjustment Adjustment Overview When replacing parts ...
Страница 686: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Страница 783: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...