4
4
4-239
4-239
Parts Replacement and Clearning > External Auxiliary System > Removing the Upper High Voltage Unit
Parts Replacement and Clearning > External Auxiliary System > Removing the Upper High Voltage Unit
Removing the Upper High Voltage Unit
<Preparation>
1. Remove the Box Cover (Left). (Refer to "Removing the DC Controller PCB")
2. Open the Controller Box. (Refer to "Removing the DC Controller PCB")
<Procedure>
1) Open the Motor Driver PCB Unit.
NOTE:
When opening the Motor Driver PCB Unit, free the top side from the protrusion.
• 5 Connectors
• Wire Saddle
• Reuse Band
x2
x5
Projection
F-4-504
2) Disconnect the connector and Grounding Wire.
• 1 Screw
x10
3) While avoiding the harness and Motor Driver PCB Unit, remove the Upper High Voltage
Unit.
• 1 Screw
F-4-505
F-4-506