![Canon ImageRunner 4045 Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/canon/imagerunner-4045/imagerunner-4045_trouble-error-codes-list_57684057.webp)
57
E197-
0011
Error in Developing High
Voltage PCB connection
detection
Connection between the Main
Driver PCB (PCB2) and the
Developing High Voltage PCB
(PCB12) is disconnected.
1. Check the connection between the Main
Driver PCB (PCB2) and the Developing High
Voltage PCB (PCB12). Main Driver side: J112,
Developing High Voltage side: J3511 2.
Replace the Developing High Voltage PCB
(PCB12).
E197-
0012
Error in Transfer High Voltage
PCB connection detection
Connection between the Duplex
Driver PCB (PCB4) and the
Transfer High Voltage PCB
(PCB13) is disconnected.
1. Check the connection between the Duplex
Driver PCB (PCB4) and the Transfer High
Voltage PCB (PCB13). Duplex Driver side:
J343, Transfer High Voltage side: J3062 2.
Replace the Transfer High Voltage PCB
(PCB13).
E197-
0181
Serial communication error
Failure of reception from the
video signal control ASIC. Data
reception was failed 5 times in a
row when reading data from the
video signal control ASIC (at FG
lock detection, BD lock
detection).
Replace the DC Controller PCB (PCB1).
E202-
0001
Scanner HP error
An error occurs during the
Scanner Unit (Paper Front) HP
detection operation (outward).
1. Connector disconnection/open circuit of the
Scanner HP Sensor (SR2). 2. Failure of the
Scanner HP Sensor (SR2). 3. Failure of the
Scanner Motor (M1). 4. Failure of the Reader
Controller PCB (PCB1).
E202-
0002
Scanner HP error
An error occurs during the
Scanner Unit (Paper Front) HP
detection operation (homeward).
1. Connector disconnection/open circuit of the
Scanner HP Sensor (SR2). 2. Failure of the
Scanner HP Sensor (SR2). 3. Failure of the
Scanner Motor (M1). 4. Failure of the Reader
Controller PCB (PCB1).
Code
Description
Remedy
E202-
0101
Glass HP error
An error occurs during the
Glass HP detection
operation (outward).
1. Connector disconnection/open circuit of the
Glass Shift HP Sensor (SR11). 2. Failure of the
Glass Shift HP Sensor (SR11). 3. Failure of the
Glass Shift Motor (M9). 4. Failure of the DADF
Driver PCB (PCB1).
E202-
0102
Glass HP error
An error occurs during the
Glass HP detection
operation (homeward).
1. Connector disconnection/open circuit of the
Glass Shift HP Sensor (SR11). 2. Failure of the
Glass Shift HP Sensor (SR11). 3. Failure of the
Glass Shift Motor (M9). 4. Failure of the DADF