30
Code
Description
Remedy
E716-
0000
Erroneous communication
with cassette pedestal
After the presence of a
cassette pedestal has
been detected, the
communication fails to be
normal for 5 sec.
1. Check the cable. 2. Replace the DC Controller
PCB (UN2). 3. Replace the Cassette Pedestal Driver
PCB.
E717-
0001
Communication error with
the NE Controller
Error when the NE
Controller is started. The
NE Controller which was
connected before turning
OFF the power is not
connected at power-on.
Check the cable, and then go through the following to
clear the error: Service Mode > COPIER >
FUNCTION > CLEAR > ERR.
E717-
0002
Communication error with
the NE Controller
IPC error at NE Controller
operation. Open circuit of
IPC, unable to recover the
IPC communication.
Check the cable, and then go through the following to
clear the error: Service Mode > COPIER >
FUNCTION > CLEAR > ERR.
E719-
0001
Error in coin manager
Error when the coin
manager is started. The
coin manager which was
connected before turning
OFF the power is not
connected at power-on.
Check the cable, and then go through the following to
clear the error: Service Mode > COPIER >
FUNCTION > CLEAR > ERR.
E719-
0002
Error in coin manager
IPC error at coin manager
operation. Open circuit of
IPC, unable to recover the
IPC communication.
When open circuit of the
pickup/delivery signal
cable is detected. Invalid
connection is detected.
Check the cable, and then go through the following to
clear the error: Service Mode > COPIER >
FUNCTION > CLEAR > ERR.
E719-
0011
Error when the Card
Reader is started
The Card Reader which
Check the cable, and then go through the following to
clear the error: Service Mode > COPIER >
FUNCTION > CLEAR > ERR.