Code
Description
Remedy
E000-
0001
Fixing temperature abnormal rise
The temperature detected by the
main thermistor does not rise to
the specified value during startup
control.
1. Go through the following to clear the
error: COPIER> FUNCTION> CLEAR>
ERR; and then turn OFF and then ON
the power. 2. Check connection of the
Connectors (Thermistor Connector:
J2063/J2510/J214, AC Connector: J105).
3. Replace the Fixing Main Thermistor
(Film Unit). 4. Replace the Fixing Main
Unit. 5. Replace the DC Controller PCB
(UN2).
E001-
0000
Fixing unit temperature rise
detection
The reading of the main thermistor
is 250 deg C or more continuously
for 200 msec.
1. Go through the following to clear the
error: COPIER> FUNCTION> CLEAR>
ERR; and then turn OFF and then ON
the power. 2. Check connection of the
Connectors (Thermistor Connector:
J2063/J2510/J214, AC Connector: J105).
3. Replace the Fixing Main Thermistor
(Film Unit). 4. Replace the Fixing Main
Unit. 5. Replace the DC Controller PCB
(UN2).
E001-
0001
Fixing unit temperature rise
detection
The hardware circuit detects
overheating of the main or sub
thermistor for 30 msec.
1. Go through the following to clear the
error: COPIER> FUNCTION> CLEAR>
ERR; and then turn OFF and then ON
the power. 2. Replace the DC Controller
PCB (UN2).
E001-
0002
Fixing unit temperature rise
detection
The reading of the sub thermistor
is 295 deg C or more continuously
for 200 msec.
1. Go through the following to clear the
error: COPIER> FUNCTION> CLEAR>
ERR; and then turn OFF and then ON
the power. 2. Check connection of the
Connectors (Thermistor Connector:
J2063/J2510/J214, AC Connector: J105).
3. Replace the Fixing Main Thermistor
(Film Unit). 4. Replace the Fixing Main
Unit. 5. Replace the DC Controller PCB
(UN2).
E002-
0000
Fixing unit temperature insufficient
rise
1. The reading of the main
thermistor is less than 115 deg C
continuously for 400 msec 2.5 sec
after it has indicated 100 deg C. 2.
The reading of the main thermistor
1. Go through the following to clear the
error: COPIER> FUNCTION> CLEAR>
ERR; and then turn OFF and then ON
the power. 2. Check connection of the
Connectors (Thermistor Connector:
J2063/J2510/J214, AC Connector: J105).
3. Replace the Fixing Main Thermistor