CRVW3 3-Channel Vibrating-Wire Datalogger
85
Press the
Check Clocks
button to instruct
LoggerNet
to send a clock check
command through the base station to the destination CRVW3 station. If the
radio link is working, the current date and time should show up in the
Adjusted
Server Date/Time
and
Station Date/Time
boxes within a few
seconds.
If
LoggerNet
returns an error after the clock check attempt, something is wrong
with the radio link or the configuration of
LoggerNet
and troubleshooting
needs to occur. Investigate at both the radio level and at the
LoggerNet
level.
In-field validation with a temporary laptop computer running
LoggerNet
helps
to validate radio links while still in the field and reduces the need to return to
the CRVW3 sites to investigate radio problems. See Section
Troubleshooting CRVW3 Networks
, for additional troubleshooting
procedures, or contact your local Campbell Scientific support representative.
If the clock check was successful, and you want the station time to be
synchronized with the
LoggerNet
computer station time, press
Set Station
Clock
. If the clock check executed successfully, the set clock operation should
also work, otherwise troubleshooting may be needed.
To add additional CRVW3 devices to your network map, you don’t need to add
a
ComPort
,
IPPort
or
PakBusPort
again. Simply click on the existing
PakBusPort
device and press
Add
. Choose
CRVWSeries
from the list of
dataloggers and press
Close
.
You will now have another CRVW3 device on
the network map. Rename it to avoid any confusion.
LoggerNet
will
automatically add numbers to the device names as they are added to make sure
they are unique (until you get a chance to rename them).
Now you can click on the new CRVW3 device, and repeat the configuration
process described earlier in this section. You will put in a unique
PakBus
Address
for each device added. You should repeat this process for every
single-hop CRVW3 device on your network (which may include CRVW3
repeater stations). Perform a clock check on each station as it is added. Don’t
forget to press
Apply
.