Appendix A. Updating CRVW3 Firmware
A-2
3.
Follow the instructions shown in this screen, including using the
Start
button to browse to the *obj file.
4.
The OS file will be read, sent to the CRVW3, and the operating system
will be loaded. A progress bar will be shown during the send process. Do
not remove power from the device during this time.
5.
After the OS is sent, a period of about 25 seconds is required to fully load
the OS and restart the device. Watch for both LEDs to flash together
rapidly just before the completion of the update. Do not attempt to connect
to the device during this time.
6.
After the load process is complete, connect to the device and confirm in
the
Main
tab or in the
Data Monitor
tab that the correct OS was loaded.
To install the OS to a remote CRVW3 using
LoggerNet
:
1.
Ensure all data is collected from the CRVW3. Consider saving the settings
of the device to an *.xml file using the
Settings
screen (
Settings Editor…
from the
Datalogger
menu of
Connect Screen
)
.
2.
Open the
Connect Screen
of
LoggerNet
and connect to the CRVW3 station
that will receive the update.
3.
Open the
File Control
screen, press the
Send…
button.
4.
Browse to the *.obj file, select it and press
Open
.
5.
Carefully review the warning, press
OK
if no further preparation is
needed, otherwise
Cancel
.
6.
The file is sent over the radio link to the remote CRVW3 and the OS
update occurs automatically.