Table 10-1: RS-232 wiring diagram
Color
Connection
Black
Power Ground
Green
RS-232 TX (output)
White
RS-232 RX (input)
NOTE:
If unable to connect to the camera using the web interface due to a loss of configuration
information, use the
Device Configuration Utility
to restore connectivity to the camera.
The CCFC comes with a Female DB9 to Terminal Block Adapter (pn 28840) that facilitates the
connection from the Power and I/O Cable to a 9 pin RS-232 connector. See
(p. 20) for wiring details.
Using the
Device Configuration Utility
:
1. Connect the camera to the serial port of a computer using the DB9 female to Terminal
Block Adapter, as shown in
2. The Status LED flashes once the camera is powered up (this can typically take 90 seconds), .
If the Status LED does not flash, press the Setup button to exit the low powered mode.
3. In the
Device Configuration Utility
, select the CCFC from the device list and click Connect to
connect to the camera.
4. Normally, the camera baud rate is set to 115200 bps. If the camera baud rate is set to
something else, select the appropriate baud rate in the
Device Configuration Utility
using
the control on the bottom left.
5. Once connected to the CCFC, use the tabs to navigate and configure the camera.
CCFC Field Camera
25
Содержание CCFC
Страница 1: ...Revision 08 2021 Copyright 2016 2021 Campbell Scientific Inc ...
Страница 134: ...24 3 NDVI NDVI functions only during daylight hours CCFC Field Camera 128 ...
Страница 137: ...FIGURE A 3 Backplate new FIGURE A 4 Backplate old CCFC Field Camera 131 ...
Страница 138: ...FIGURE A 5 CCFCCBL3 L Ethernet connector new FIGURE A 6 CCFCCBL2 L Ethernet connector old CCFC Field Camera 132 ...