Table 9-1: Power and I/O cable connections
Color
Function
Connection
When Not Used
White
RS-232 RX (Input)
RS-232 Output (TX control port of a
data logger or pin 3 of a computer
(DTE) DB-9 connector).
RS-485B when configured to RS-485.
Only connect when RS-232 and RS-
485 communications are used for
PakBus® or
Device Configuration
Utility
.
Connect to wire
terminator/connector
(
Yellow
Modem Power
Control (Output)
Powers a communication device. The
camera switches the input power
voltage to this line.
For solar powered sites the camera can
remove power from the modem when
communications are not required.
Connect to wire
terminator/connector
(
Blue
External Trigger
(Input)
Connect to external signal source
(data logger control terminal). The
external signal wakes up or initiates
photo/video acquisition. On a
Campbell Scientific data logger,
connect to a 5 V (5V) or switched 12 V
(SW12V) terminal and be sure to
provide a ground.
Another device can also help keep the
camera in the Fully On power mode by
leaving the External Trigger Input
activated.
Connect to ground if left
in factory default settings
Clear
1
Shield
Earth ground or
⏚
when the RS485
configuration is used.
1
Required
2
For the CR300 Series, 100 ohm resistor to the TX (green) line recommended when sending images to the data
logger.
CCFC Field Camera
22
Содержание CCFC
Страница 1: ...Revision 08 2021 Copyright 2016 2021 Campbell Scientific Inc ...
Страница 134: ...24 3 NDVI NDVI functions only during daylight hours CCFC Field Camera 128 ...
Страница 137: ...FIGURE A 3 Backplate new FIGURE A 4 Backplate old CCFC Field Camera 131 ...
Страница 138: ...FIGURE A 5 CCFCCBL3 L Ethernet connector new FIGURE A 6 CCFCCBL2 L Ethernet connector old CCFC Field Camera 132 ...