INSTRUCTIONAL MANUAL
2750L-P/4500L-P/6000L-P
August, 2001
Rev. K
-79-
<SP> 65.5 <CR> <LF>
The foregoing assumes an apparent output power on phase A of 65.5 VA.
3.8.5
NORMAL CONDITION RESPONSES
All normal condition responses of the power source to requests from the bus controller (either status or measurement
requests) begin with an ASCII space <SP>. In the following examples of bus controller/power source exchange, (L)
indicates the power source is listen addressed and (T) indicates it is talk addressed.
When the power source is requested to measure one of the parameters identified by a noun modifier (e.g., VOLT), the
following strings are sent and received by the bus controller:
(L) FNC ACS VOLT :CH01 <CR> <LF>
(L) INX VOLT <CR> <LF>
(T) <SP> "default time out" <CR> <LF>
(L) FTH VOLT <CR> <LF>
(T) <SP> 115.5 <CR> <LF>
When the power source receives an STA OP-code after a CNF OP-code, its normal response is an ASCII space <SP>.
An example of the strings transmitted and received is:
(L) CNF <CR> <LF>
(L) STA <CR> <LF>
(T) <SP> <CR ><LF>
The power source accepts the STA OP-code after any string which is sent to it. For example:
(L) FNC ACS :CH00 SET VOLT115 SRX VOLT 135 SRN VOLT5 <CR><LF>
(L)
STA
(T) <SP> <CR> <LF>
3.8.6 ABNORMAL
CONDITION RESPONSE
When an abnormal condition has been detected by the power source, its response to the STA OP-code will begin with
an ASCII F. The abnormal condition may be in the power source or specifically in the power source controller. In the
examples that follow, (MOD) is an abbreviation for MODULE and refers to the power controller; (DEV) is an
abbreviation for DEVICE and refers to the power source excluding the power controller. The response string for an
abnormal condition is:
F07ACS01 <SP> (DEV): <SP> "message"<CR> <LF>
The status contained in "message" may be similar to the following:
OUTPUT CH01&02&03 VOLT FAIL
OUTPUT CH01&02&03 TEMPERATURE FAIL
CONTROLLER CH01&02&03 FREQ FAIL
Where a & means "and".
When an STA OP-code is transmitted after any string, the complete abnormal response may be similar to:
F07ASC01 <SP> (MOD) : <SP>"message"<CR> <LF>
Содержание 12000L-1P
Страница 27: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 23 Figure 2 3 FUNCTION TEST SETUP...
Страница 98: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 94 Figure 4 3 FLOW DIAGRAM A REMOTE CALIBRATION...
Страница 99: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 95 Figure 4 3 FLOW CHART continued...
Страница 108: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 104 This page left intentionally blank...
Страница 110: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 106 Figure 5 1 AC POWER SYSTEM BLOCK DIAGRAM...
Страница 114: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 110 This page left intentionally blank...
Страница 119: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 115 Figure 6 1 MODULE LOCATION...
Страница 120: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 116 This page left intentionally blank...
Страница 133: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 129 Figure 1 STEADY STATE VOLTAGE...
Страница 135: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 131 Figure 8 9 FREQUENCY TRANSIENT...
Страница 136: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 132 Figure 10 11 ABNORMAL OPERATION...
Страница 137: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 133 Figure 12 13 ABNORMAL FREQUENCY...
Страница 138: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 134 Figure 14 EMERGENCY VOLTAGE...
Страница 140: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 136 This page left intentionally blank...
Страница 148: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 144 FIGURE 2...