INSTRUCTIONAL MANUAL
2750L-P/4500L-P/6000L-P
August, 2001
Rev. K
-52-
Any header that is sent without an argument will cause the front display to show the corresponding screen. Refer to
Figure 3-5 for a summary of all possible command sequences.
Figure 3-5
REMOTE COMMEND SEQUENCES
IEEE-488 PROGRAM SYNTAX
TO PROGRAM OUTPUT PARAMETERS:
AMP - - -(n)
Æ
OPN
Æ
WVF- - - SNW
Æ
SNC - INT
Æ
REC-(n)
Æ
REG-(n)
Æ
*
Æ
FRQ A CLS
A SQW CLK EXT
CRL
B
B
RNG
C
C
PHZ
DRP
---------------------------
Æ
-------------
Æ
--------------------------------
Æ
---------------------------
Æ
------------
Æ
----------
Æ
TO RAMP OR STEP ONE OUTPUT PARAMETERS:
AMP - - -
(n)
Æ
STP - (n)
Æ
DLY - (n)
Æ
VAL - (n)
Æ
*
Æ
FRQ
A |
CRL
B
Æ
DLY – (n)
Æ
VAL – (n) -------------
Æ
*
PHZ
C
TO RAMP OR STEP TWO OUTPUT PARAMETERS:
AMP - - -(n)
Æ
AMP - - - (n)
Æ
STP – (n)
Æ
DLY – (n)
Æ
VAL – (n)
Æ
STP – (n)
Æ
*
Æ
FRQ
A
FRQ A |
CRL
B
CRL B ----------
Æ
DLY – (n)
Æ
VAL – (n)
Æ
VAL – (n)---------
Æ
*
PHZ
C PHZ
C
TO REQUEST TALKING OF CALIBRATION COEFFICIENTS:
Æ
TLK
Æ
CAL -- -------
- -
------------
Æ
*
AMP
A
VLT
B
PWR
C
CUR
TO PROGRAM THE OUTPUT MODE
Æ
MOD PHS > 1
------------
Æ
*
3
TO SPECIFY THE SERVICE REQUEST INTERRUPT:
-----
Æ
SRQ – (n) ----
Æ
*
Содержание 12000L-1P
Страница 27: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 23 Figure 2 3 FUNCTION TEST SETUP...
Страница 98: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 94 Figure 4 3 FLOW DIAGRAM A REMOTE CALIBRATION...
Страница 99: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 95 Figure 4 3 FLOW CHART continued...
Страница 108: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 104 This page left intentionally blank...
Страница 110: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 106 Figure 5 1 AC POWER SYSTEM BLOCK DIAGRAM...
Страница 114: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 110 This page left intentionally blank...
Страница 119: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 115 Figure 6 1 MODULE LOCATION...
Страница 120: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 116 This page left intentionally blank...
Страница 133: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 129 Figure 1 STEADY STATE VOLTAGE...
Страница 135: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 131 Figure 8 9 FREQUENCY TRANSIENT...
Страница 136: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 132 Figure 10 11 ABNORMAL OPERATION...
Страница 137: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 133 Figure 12 13 ABNORMAL FREQUENCY...
Страница 138: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 134 Figure 14 EMERGENCY VOLTAGE...
Страница 140: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 136 This page left intentionally blank...
Страница 148: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 144 FIGURE 2...