70
Performance checking
Signal Generator
pre-2003 model
7. Gradually reduce the Signal Generator power output
by turning the ‘ON-OFF/Level’ control anti-clockwise.
CORRECT RESULT
: The Function Checker bar graph should
show a corresponding decrease in indication to zero.
8. Reset the Signal Generator to full power using the
‘ON-OFF/Level’ control. Change the ‘Pulsed/Continuous’
switch on the Signal Generator to the ‘down’ position (pulsed).
CORRECT RESULT
: The Function Checker bar graph should
now be flickering to indicate a pulsed signal. The Signal
Generator audio tone will change from a continuous tone
to a pulsed tone.
9. Change the ‘Loud/Mute’ switch on the Signal Generator
to the ‘down’ position (mute).
CORRECT RESULT
: The Function Checker response should
remain unchanged but the audio output from the Signal
Generator should be quieter.
Function Checker
Function Checker
<
<
Function Checker
<